Search PubMedSearch

PubMed · 2643764

Solid-state imagers for microscopy.

Abstract

Solid-state imagers offer a variety of options to the modern optical microscopist. Photodiode arrays, charge injection devices, and charge-coupled devices are the three basic types of solid-state imagers available for research imaging. The charge-coupled device (CCD) is the solid-state imager of choice, because of its superior characteristics and its widespread acceptance in the research environment. The performance characteristics of the CCD are well documented and understood, having been quantified by many experimenters, especially in the physical sciences. CCDs exhibit dynamic ranges up to 50,000:1, very high quantum efficiency, and ultralow noise. The camera system in which a device is used, however, dictates the overall performance which can be achieved. The CCD imaging system as it applies to cell biology is discussed in detail in Hiraoka et al. (1987). A video camera operating at 30 frames/second does not provide the resolution, low noise, dynamic range, and linearity of a slow scan, cooled camera operating at 1 frame/second. Conversely, a slow scan camera does not offer the user the facility to resolve rapidly changing events in real time. The analogy between an 8-mm movie camera (video camera) and a 35-mm snapshot camera (slow scan cooled camera) is a useful one to emphasize the different character of these two electronic imaging systems. These two basic camera systems both employ CCD imagers, and each has very different, but complementary, characteristics. No one camera system can address the wide variety of imaging problems which face the modern microscopist. The user of this new generation of instrumentation must decide which system best fits the problem at hand.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R S Aikens, D A Agard, J W Sedat. 1989. Solid-state imagers for microscopy.. https://doi.org/10.1016/s0091-679x(08)60199-5

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Determination of eperisone in human plasma by gas chromatography-mass spectrometry.

A gas chromatographic-mass spectrometric method was developed to determine eperisone hydrochloride, 4'-ethyl-2-methyl-3-piperidinopropiophenone hydrochloride, in human plasma over the concentration range 0.2-40 ng/ml. Excellent sensitivity was achieved by selection of a favorable fragment ion, m/z 98, of eperisone and reduction of heat decomposition of eperisone by using a splitless injector and a shortened capillary column. The method described here allows the determination of plasma concentrations as low as 0.2 ng/ml, the concentration attained 6 h after a single oral administration of 50 mg. At eperisone hydrochloride concentrations higher than 0.5 ng/ml, the mean inter-day variation of accuracy of the assay was less than 12%.

Calibration

Video analysis of DNA sequence homologies.

A method for the rapid quantitative analysis of dot blot assays is presented. A video camera, an NTSC compatible frame grabber board, and an AT personal computer are used to read photographic exposures of the assay plate. Image processing and image analysis techniques are used to calculate the orientation of the dot raster and then to compensate for the effect of variations in field illumination on measurements of local contrast. Local contrast (between dots and background) is an exponential function of the amount of hybridization between blotted DNA and complimentary oligonucleotide probes. The amount of hybridization between blotted DNA and oligonucleotide probes of known sequence is the criteria used to establish HLA-DR tissue types. Although the assay described here utilizes a chemiluminescent reaction, this algorithm may be used to read any assay that produces a rectangular raster of dots.

Calibration

Analysis of terbutaline in human plasma by high-performance liquid chromatography with electrochemical detection using a micro-electrochemical flow cell.

A high-performance liquid chromatographic method is described for the determination of terbutaline in human plasma in the range 1-35 ng/ml. Detection was achieved using a carbon fibre micro-electrochemical detector and a column-switching system. The microelectrode cell has advantages over conventional glassy carbon electrode-based detection systems in that it is easy to prepare, flexible in its operation and suffers less trouble from problems such as air bubbles and leaks. Furthermore, it has a better detection limit for terbutaline (0.8 ng/ml) to that obtained using a conventional glassy carbon electrode flow detector (2 ng/ml). Sample clean-up was by on-line solid-phase extraction with column switching, providing a method which was sensitive and reproducible, where the mean overall coefficient of variation was 5.60% and drug recovery in excess of 86% at the concentration levels studied.

Calibration