Search PubMed⌕ Search

PubMed · 2614875

Right ventricular function under acute cor pulmonale.

Abstract

Many investigators have reported the hemodynamics in acute cor pulmonale clinically and experimentally. However, earlier studies have not made quantitative evaluations of the effects of coronary perfusion pressure and hypoxia on right ventricular contractility. We simulated acute cor pulmonale in nine isolated canine hearts and investigated the relationship of the process to cardiac deterioration and restoration. The afterload and preload of the right ventricle were controlled with a computer-assisted load control servosystem. Coronary perfusion pressure (COPP) was also controlled at either normal or variable levels identical to products of measured cardiac output and assumed values of systemic vascular resistance. Critical state (CS) was defined as a condition with an initial decrease in peak systolic pressure despite increased afterload. Within the normal range of PaO2 (105 +/- 5.3 mmHg), CS developed at a COPP of 51 +/- 5.1 mmHg, while under low PaO2 (51 +/- 2.3 mmHg), it developed at a COPP of 59 +/- 8.8 mmHg. As long as the COPP was normal (90 mmHg), the contractility of the right ventricle did not decrease despite hypoxia (PaO2 51 +/- 2.3 mmHg). An increase in systemic vascular resistance or administration of a beta-stimulant at CS restored the contractility of the right ventricle. However, an increase in preload decreased the contractility of the right ventricle.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K Sekioka, T Tanaka, T Hayashi, T Yamaguchi, N Ono, T Nakano. 1989. Right ventricular function under acute cor pulmonale.. https://doi.org/10.1253/jcj.53.1269

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The effect of acute pain crisis on exhaled nitric oxide levels in children with sickle cell disease.

Exhaled nitric oxide (FE(NO)) has been shown to be decreased in children with sickle cell disease. We sought to evaluate the effect of sickle cell vaso-occlusive crisis (VOC) on FE(NO) levels. We measured FE(NO) levels in 42 children with sickle cell disease, 29 in their baseline health and 13 during an acute VOC. There was no difference in FE(NO) levels between children at baseline (15.12 +/- 9.32 ppb) and those during an acute VOC (15.68 +/- 7.26 ppb; P = 0.794). FE(NO) is not a useful marker of acute VOC in children with sickle cell disease.

Acute Disease↗

[Megadolichobasilar anomaly causing acute deafness with vertigo].

Megadolichobasilar anomaly, a dilatant arteriopathy of the basilar artery attributable to chronic arterial hypertension, can cause cranial nerve compression syndromes of the cerebellopontine angle or infarcts of the vertebrobasilar circulation. In this paper, we report on a patient with known megadolichobasilar anomaly and a partially thrombosed fusiform aneurysm of the basilar artery, who presented with acute-onset vertigo and subsequent deafness due to thromboembolic occlusion of the labyrinthine artery. Because of the vascular origin of the patient's symptoms, his vertigo disappeared over time while the deafness persisted.

Acute Disease↗

Retrieval of a leaflet escaped in a Tri-technologies bileaflet mechanical prosthetic valve.

The escape of the prosthetic heart valve disc is one of the causes of prosthetic dysfunction that requires emergency surgery. The removal of the embolized disc should be carried out because of the risk of a progressive extrusion on the aortic wall. Several imaging techniques can be used for the detection of the missing disc localization. In this report we describe a 32-year-old man who underwent mitral valve replacement with a Tri-technologies bileaflet valve three years ago, and was admitted in cardiogenic shock. Transesophageal echocardiography showed acute-onset massive mitral regurgitation. The patient underwent emergency replacement of the prosthetic valve. Only one of the two leaflets remained in the removed prosthetic valve. The missing leaflet could not be found within the cardiac cavity. The abdominal fluoroscopic study and plain radiography were unable to detect the escaped leaflet. The abdominal computed tomography scan and the ultrasound showed the escaped leaflet in the terminal portion of the aortic bifurcation. To retrieve the embolized disc laparotomy and aortotomy were performed three months later. The escaped leaflet shows a fracture of one of the pivot systems caused by structural failure. This kind of failure mode is usually the result of high stress concentration.

Acute Disease↗