Reticulocyte counting using flow cytometry.

Abstract

A flow cytometric method for the quantitation of reticulocytes was refined for routine laboratory use. Blood (2 microliters) is added to 2 ml of 0.4 microM thiazole orange in phosphate buffered saline, incubated at room temperature for 90 minutes, and analysed on a Coulter EPICS Profile flow cytometer, with gating for red cells on the basis of forward and right angled light scatter. Blood (2 microliters) is also incubated with phosphate buffered saline alone as an unstained control. The adult reference range (mean +/- 2 SD), established from 30 laboratory personnel, is 19.4-59.2 x 10(9)/l (0.2-1.6%). Comparison of this technique was made on 39 selected patient samples with visual counting of cells stained with brilliant cresyl blue. The correlation between the two methods was 0.99 with slope 0.96 and intercept 0.02. The precision of the automated technique in three subjects with reticulocyte counts of 0.12%, 1.84%, and 14.3% was 33.3%, 7.3%, and 1.4%, respectively (coefficient of variations). In three patients studied serially after intensive chemotherapy, in whom the reticulocyte count quantitated by routine visual methods approached zero (0-0.1%) for eight to 18 days, the automated counts varied between 0 and 0.5%. Flow cytometric reticulocyte counting is thus a simple and highly reliable methodology for the quantitation of normal and raised reticulocyte counts but cannot be reliably used to quantitate a subnormal level.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P R Nobes, A B Carter. 1990. Reticulocyte counting using flow cytometry.. https://doi.org/10.1136/jcp.43.8.675. https://searchpubmed.org/record/pubmed%3A2401736/reticulocyte-counting-using-flow-cytometry

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Search PubMed by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related citations

Design, synthesis and biological evaluation of hydroxybenzothiazole-linked benzothiazole/benzoxazole conjugates as potent dual α-amylase and α-glucosidase inhibitors.

The current study focuses on the synthesis and evaluation of novel Hydroxybenzothiazole-Linked Benzothiazole/Benzoxazole Conjugates to target Diabetes Mellitus (DM) by inhibiting α-amylase and α-glucosidase. Spectroscopic methods, including 1H and 13C NMR spectroscopy, were employed to confirm the structures of newly synthesized conjugates. The findings of in-vitro analysis displayed that the synthesized derivatives inhibited α-amylase and α-glucosidase enzymes with IC50 values ranging from 3.65 ± 0.20 μM to 32.15 ± 3.20 μM on α-amylase and 5.92 ± 0.80 μM to 35.60 ± 3.40 μM on α-glucosidase, in contrast to the reference drug Acarbose (α-amylase IC50 = 8.25 ± 0.80 μM; α-glucosidase IC50 = 10.75 ± 1.10 μM). Among the series 9a-9f and 10a-10f, analogs 10 f, 10b, 9b, and 9e displayed superior anti-diabetic activity compared to the reference drug Acarbose. The inhibitory activity of these conjugates can be attributed to their favorable and stable interactions with critical amino acid residues of targeted enzymes, as revealed through molecular docking analysis. ADMET predictions and drug-likeness evaluations showed favorable pharmacokinetic features, while DFT investigations revealed electronic insights related to bioactivity. Experimental outcomes and in silico support display that these potent Hydroxybenzothiazole-Linked Benzothiazole/Benzoxazole Conjugates were comparable to an existing diabetic mellitus inhibitor while conserving an acceptable safety profile, specifying potential for further therapeutic development and optimization against diabetic Mellitus.

Benzothiazoles↗

Valvular heart disease in Parkinson's disease patients treated with dopamine agonists: a reader-blinded monocenter echocardiography study.

Fibrotic valvular heart disease (VHD) has been reported in association with ergot dopamine agonists (DAs), but the current database is insufficient regarding clinical relevance and comparison to data on non-ergot DAs. We evaluated the effects of four DAs (pergolide, cabergoline, ropinirole, pramipexole) on morphology and function of heart valves in patients with Parkinson's disease (PD) to determine the frequency and clinical relevance of DA-induced VHD. A total of 85 patients treated with ergot or non-ergot DAs and 38 age-matched controls were evaluated by transthoracic echocardiography. Valvular pathology was assessed by established criteria of valvular regurgitation and a VHD scoring system. Both grading systems revealed increased frequency of VHD in ergot DA patients compared to both non-ergot DA patients and controls with 22% of ergot DA patients having moderate VHD versus 3% of non-ergot DA patients and none of controls (P = 0.001). We did not find correlations of echocardiographic findings with duration/cumulative dose of treatment, age, or vascular risk factors. Our data suggest that ergot DAs are associated with higher prevalence of VHD compared to non-ergot DAs and controls. Standard echocardiography seems sufficient to detect VHD in PD patients treated with DAs.

Benzothiazoles↗

Detection and quantification of hepatitis B virus DNA by SYBR green real-time polymerase chain reaction.

A single-round real-time polymerase chain reaction (PCR) assay based on SYBR green dye technology for the detection and quantification of hepatitis B virus (HBV) DNA in serum was evaluated and compared with a qualitative nested PCR and the Cobas Amplicor HBV Monitor assay (Roche Molecular Diagnostics, Milan, Italy). The performance of the real-time PCR assay was evaluated in a routine clinical laboratory setting with a total of 212 clinical specimens. The sensitivity of the real-time PCR corresponded to 31 IU/ml (70 copies/ml), and comparison with the qualitative nested PCR showed significant concordance for 94% of samples. The linear curve over 7 log units, spanning 10(3)-10(9) IU/ml (2.28 x 10(3) to 2.28 x 10(9) copies/ml), was observed in the quantitative determination. The interexperimental variability coefficient of the assay ranged from 0.22 to 0.39 and the intraexperimental variability coefficient from 0.24 to 0.41. By excluding values outside of the dynamic ranges of both tests, the HBV Monitor and the real-time PCR gave an agreement within +/-1 log unit for 90% of samples, while those for the remaining 10% were found to be above 1 log unit but less than 1.5 log units. When the results inside and outside the dynamic range of the HBV Monitor were examined, 90% of the results were in agreement. In conclusion, the real-time PCR based on SYBR green technology proved suitable for routine diagnostic purposes, showing good sensitivity, high specificity, high reproducibility, and good linearity over a broad dynamic range of quantification.

Benzothiazoles↗