Search PubMedSearch

PubMed · 239004

The pulse current pattern generated by developing fucoid eggs.

Abstract

Using a newly developed extracellular vibrating electrode, we have made the first study of the spatial distribution of the growth currents around a single developing egg. This pattern was studied during the current pulses wihic traverse two-celled Pelvetia embryos. These pulses can be stimulated to occur with a periodicity of 70 min by mild acidification of the dea water medium. Current enters only at the growing rhizoid's tip while leaving both the base of the rhizoid cell and the whole outer membrane of the thallus cell. The field in front of the rhizoid cell falls off as the inverse cube of the distance from the rhizoid cell's center in the manner of a dipole field. The total inward and outward currents are equal, agreeing with theory. The current density at the rhizoid cell's base is twice that at the top of the thallus cell and this probably represents a change in the outer membrane's properties. There are no significant differences in the durrent density over the thallus cell. These results suggest a model in which the pulse current leaks in through newly opened channels in the growing tip and leaks out elsewhere due to the resultant fall in the membrane potential.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R Nuccitelli, L F Jaffe. 1975. The pulse current pattern generated by developing fucoid eggs.. https://doi.org/10.1083/jcb.64.3.636

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effect of aging the hollow cathode by sputtering on the analytical precision of the hollow cathode discharge emission source.

Sputtering changes the analytical performance of the hollow cathode as an emission source. Proper conditioning (aging) of the hollow with sputtering greatly improves precision. Conditioning decreases the blank emission signal and changes the shape of the hollow. Micrographs which show the evolution of the bottom of the hollow into a stable bulb shape are presented. The blank emission signal decreases with aging of the hollow and approaches a constant value when the hollow is properly conditioned. A short-term stability (n = 5) of approximately 1.8% RSD has been observed frequently. An average long-term stability over several days (n = 45) of 4.5% for Li and 3.5% for Na in the emission signal from microsamples (less than 50 nL) deposited in the hollow cathode discharge source is reported here. Instrumentation, operation, and sample preparation procedures are described.

Electrodes