Search PubMed⌕ Search

PubMed · 2304533

Synthetic tips.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K E Drexler, J S Foster. 1990-02-15. Synthetic tips.. https://doi.org/10.1038/343600b0

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Near field optical microscopy in aqueous solution: implementation and characterization of a vibrating probe.

Near field optical microscopy (NSOM) is one of the possible solutions to circumvent the diffraction limit, but the control of the optical probe in solution has been a technical challenge for practical applications. Most recently, it has been shown that the pipette used in the scanning ion conductance microscope can be modified to form a high resolution near field optical probe. When combined with a novel distance modulation mechanism, a robust near field microscope can be constructed for operation in aqueous solution. In this paper, we present technical details of this design and a further characterization of the NSOM system for imaging in solution. Fundamental limitations of this approach in comparison to other systems are also discussed. Based on the current technology, it is concluded that better than 50 nm resolution should be achievable with this technique for fluorescence, as well as fluorescence resonance energy transfer, imaging of biological specimens.

Microscopy↗

Time-resolved detection of singlet oxygen in a transmission microscope.

The time-resolved absorption spectrum of singlet oxygen [O2(a1 delta g)-->O2(b1 sigma g+)] has been recorded in the region approximately 5100-5300 cm-1 from air-saturated polystyrene samples using a microscope attached to a step-scan Fourier transform IR spectrometer. Singlet oxygen signals were observed with a time resolution of approximately 160 ns from sample volumes of approximately 20 nL using moderate data-acquisition times. These data indicate that it is reasonable and worthwhile to consider the further development of a transmission microscope as a viable tool to create singlet oxygen images of inhomogeneous samples including samples of biological importance.

Microscopy↗

[Microscopic identification of Rhodiola henryi].

OBJECTIVE: To study the microscipic characteristics of the rhizoma, root, stem, leaf and powder of Rhodiola henryi. METHOD: By microscopic observation. RESULTS: The brown substance was always found in the rhizoma and root of Rhodiola henryi. There was a fiber ring in the cambium region of the stem, and some fiber bundles surrounded the pholem. The epidemis cells of the leaf were different in size, and some were very large. Most stomata were anisocytic. The pollen grains were spherical or oblate, with irregularly reticular veins on the outer walls and three germ pore furrows. CONCLUSION: The above-mentioned characteristics provided a basis for the identification of Rhodiola henryi.

Microscopy↗