["Mixing" of implants, a basic problem].

Abstract

The so-called "mixing" of implants and instruments of different producers in hospitals leads to some risks. The use of standardized implant materials (e.g. stainless steel ISO 5832/1) by different producers is necessary but not sufficient for combining an osteosynthesis plate and a bone screw from different sources. The design, the dimensions and tolerances, the manufacturing, the quality control, the well tested applicational technique can be different too for the implants and the necessary instruments as well. This may lead to damage, failure or fracture of the biomechanical system called "osteosynthesis", that means failure of the therapy. Finally the patient pays for the problems. Some examples illustrate the potential problems for the involved staff or institutions. The use of a unique consistent well tested and approved set of implants and instruments must be recommended strongly to avoid any additional risk.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

F Baumgart. 1990. ["Mixing" of implants, a basic problem].. https://pubmed.ncbi.nlm.nih.gov/2269639/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[Value of routine follow-up after infrainguinal arterial reconstruction].

Longterm patency of infrainguinal bypass procedures may be established on the basis of clinical evaluation and ankle pressure measurements. With the aim of assessing whether these parameters could predict grafts at risk for occlusion, we identified 24 patients in whom the bypass had occluded between 3 and 12 months postoperatively, but following at least one follow-up. These patients were compared with a control group consisting of further 24 patients operated on during the same period, but in whom the bypass was patent. Prior to graft occlusion only nine (39%) patients had complained of claudication, and a significant drop in ankle pressure was demonstrated in seven (29%) patients. These figures were significantly higher than the one (4%) patient in the control group who complained of claudication and the other (4%) patient who developed a drop in ankle pressure (p < 0.02 and 0.05, respectively). Graft surveillance based on patients' history and ankle pressure measurements are insufficient parameters for identification of grafts at risk for occlusion. However, the occurrence of claudication and/or a significant drop in ankle pressures are associated with a high incidence of graft thrombosis.

Biocompatible Materials

[Implantation of a Stecker metal prosthesis in malignant stenosis of the gastric stump].

A 55 year old patient 3 years after gastric resection (Billroth II) has got gastric outlet stenosis. Half year ago was established a tumour recidive, that the time of reoperation was inoperable. Under endoscopic and radiological control we have introduced and placed a 19 mm diameter, 4 cm long balloon expandable tantalum stent (Strecker stent). The gastric passage has normalised and after 6 month the patient is symptom free.

Biocompatible Materials