Electron backscattering. Implication to electron dosimetry.

Abstract

Plane-parallel electron chambers have structures made of plastic materials of low atomic number which do not provide the same scattering into the sensitive volume as water and suitable correction factors are therefore required to allow for this effect. Hunt et al. (1988) measured electron backscatter in low atomic number materials and this data was, in this work, analyzed together with the experimental data obtained for higher atomic number materials published earlier (Klevenhagen et al., 1982). It was found that both sets of data correlate well and fit to an empirical exponential expression for which the necessary calculation parameters were derived. This expression enables suitable backscatter correction factors to be calculated for materials of atomic numbers between 4 and 82, including plastics, and electron energies between 3 and 35 MeV. The deficiency of backscatter was evaluated for the most popular materials used in the construction of electron chambers and this data may be used for corrections.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

S C Klevenhagen. 1990. Electron backscattering. Implication to electron dosimetry.. https://pubmed.ncbi.nlm.nih.gov/2251410/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Technical note: reconstructing dose distributions from manually planned electron boosts in breast radiotherapy.

PURPOSE: In breast radiotherapy, delivery of manually-calculated electron boosts limits retrospective dose-response analyses as dose distribution is unavailable. This work evaluates the feasibility of reconstructing dose distributions from manually planned electron boosts in breast-conserving radiotherapy. METHODS: Only 72 out of 198 breast cancer patients had complete stored dose distributions from sequential electron boosts in the REQUITE study. Arbitrary data from 70/72 patients were used to develop and validate dose reconstruction method. Twenty patients were used to determine optimal parameters for Monte-Carlo-based (MC) electron dose reconstruction on RayStation (v.11B-R), considering CT-calibration curve, MC-history number, andcalculation grid resolution. Remaining 50 patients were used to quantify dose reconstruction accuracy. The similarity between reconstructed and stored dose was evaluated using 3D-gamma index and dosimetric parameters extracted from breast and tumour bed contours. Dose difference location was evaluated using dose-location histogram. RESULTS: Calculation grid resolution significantly impacted electron dose distribution (p&#xa0;<&#xa0;0.01), where the finest grid (0.15&#xa0;cm) showed highest similarity to stored doses. CT-calibration curve and MC-history number had a negligible influence on dose reconstruction. Dosimetric difference between reconstructed and stored doses was&#xa0;<&#xa0;1&#xa0;Gy for breast and tumour bed. Reconstructed dose was achieved&#xa0;>&#xa0;90% gamma passing rate in the validation set. However, around 2.5&#xa0;Gy dose differences were observed at the skin and tissue interface regions. CONCLUSIONS: Retrospective electron boost dose reconstruction is feasible with acceptable accuracy, and could increase data completeness in large cohort studies. Caution is advised when assessing dose near tissue interface and further validation is needed outside the REQUITE dataset.

Electrons↗

Study of the binding affinity for corticosteroid-binding globulin (CBG) using the electron topological method (ETM) as three-dimensional quantitative structure-activity relationship (3D QSAR).

The Electron Topological Method, called ETM, is a descriptor for predicting the biological activities of molecules based on three-dimensional quantitative structure-activity relations (3D QSAR). ETM uses a modified electron topological state index to substitute for electronic properties and a topological distance for the relative distance in the molecule. It is shown that the molecular fragments responsible for this activity possess fixed electronic and geometric characteristics associated with a distinct arrangement and the steric accessibility of an oxygen atom and a group of carbon atoms. After that, it is essential to employ a linear regression analysis technique to derive a 3D QSAR model relating the biological activities to the ETM. The ETM is used to study the 3D QSAR of the corticosteroid-binding globulin (CBG) binding affinity to 31 steroids, and resulting models have a comparable to current 3D methods such as CoMFA. Though the ETM is a descriptor based on 3D topological information obtained by quantum chemical derived descriptors, give the best answer for both the similarity analysis and the statistical fitting.

Electrons↗

Electron-conformational study for the structure-hallucinogenic activity relationships of phenylalkylamines.

The structure-hallucinogenic activity relationships of a series of phenylethylamine and phenylisopropylamine derivatives have been investigated in the frameworks of electron-conformational method. The calculated geometry and electronic structure parameters accompanying to each atom and bond of each molecule in view were arranged as a matrix called electron-conformational matrix of contiguity (ECMC). The features that are responsible for strong and weak activity demonstrations have been found as submatrices of ECMCs belonging to some template compounds. Two electron-conformational features present in nonhallucinogenic compounds have been revealed. A quantitative model has been improved for predicting hallucinogenic activity numerically. A test series was used to verify the results obtained.

Electrons↗