Search PubMed⌕ Search

PubMed · 2231101

Multidimensional digital image representations using generalized Kaiser-Bessel window functions.

Abstract

Inverse problems that require the solution of integral equations are inherent in a number of indirect imaging applications, such as computerized tomography. Numerical solutions based on discretization of the mathematical model of the imaging process, or on discretization of analytic formulas for iterative inversion of the integral equations, require a discrete representation of an underlying continuous image. This paper describes discrete image representations, in n-dimensional space, that are constructed by the superposition of shifted copies of a rotationally symmetric basis function. The basis function is constructed using a generalization of the Kaiser-Bessel window function of digital signal processing. The generalization of the window function involves going from one dimension to a rotationally symmetric function in n dimensions and going from the zero-order modified Bessel function of the standard window to a function involving the modified Bessel function of order m. Three methods are given for the construction, in n-dimensional space, of basis functions having a specified (finite) number of continuous derivatives, and formulas are derived for the Fourier transform, the x-ray transform, the gradient, and the Laplacian of these basis functions. Properties of the new image representations using these basis functions are discussed, primarily in the context of two-dimensional and three-dimensional image reconstruction from line-integral data by iterative inversion of the x-ray transform. Potential applications to three-dimensional image display are also mentioned.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R M Lewitt. 1990. Multidimensional digital image representations using generalized Kaiser-Bessel window functions.. https://doi.org/10.1364/josaa.7.001834

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Does the structure of the water-oxidizing photosystem II-manganese complex at room temperature differ from its low-temperature structure? A comparative X-ray absorption study.

Detailed information on room-temperature structure and oxidation state of the Photosystem II (PS II) manganese complex is needed to put mechanistic considerations on solid grounds. Because previously this information had not been available, the tetranuclear manganese complex was investigated by X-ray absorption spectroscopy (XAS) on PS II membrane particles at 290 K. Due to methodical progress (collection of XAS spectra within 10 s or less), significant X-ray radiation damage can be avoided; room-temperature XAS investigations on the PS II in its native membrane environment become feasible. Thus, the ambiguity with respect to the mechanistic relevance of low-temperature XAS results is avoidable. At 290 K as well as at 18 K, the manganese complex in its dark-stable state (S(1)-state) seemingly is a Mn(III)(2)Mn(IV)(2) complex comprising two di-mu(2)-oxo bridged binuclear manganese units characterized by the same Mn-Mn distance of 2.71-2.72 A at both temperatures. Most likely, manganese oxidation states and the protonation state of the bridging oxides are fully temperature independent. Remarkably, at room-temperature manganese-ligand distances of 3.10 and 3.65 A are clearly discernible in the EXAFS spectra. The type of bridging assumed to result in Mn-Mn or Mn-Ca distances around 3.1 A is, possibly, temperature-dependent as suggested by distance lengthening upon cooling by 0.13 A. However, mechanistic proposals on photosynthetic water oxidation, which involve the dimer-of-dimers model [Yachandra, V. K., et al. (1993) Science 260, 675-679] are not invalidated by the presented results.

Fourier Analysis↗

The 'fingerprint' that X-rays can leave on structures.

BACKGROUND: Exposure of biomacromolecules to ionising radiation results in damage that is initiated by free radicals and progresses through a variety of mechanisms. A widely used technique to study the three-dimensional structures of biomacromolecules is crystallography, which makes use of ionising X-rays. It is crucial to know to what extent structures determined using this technique might be biased by the inherent radiation damage. RESULTS: The consequences of radiation damage have been investigated for three dissimilar proteins. Similar results were obtained for each protein, atomic B factors increase, unit-cell volumes increase, protein molecules undergo slight rotations and translations, disulphide bonds break and decarboxylation of acidic residues occurs. All of these effects introduce non-isomorphism. The absorbed dose in these experiments can be reached during routine data collection at undulator beamlines of third generation synchrotron sources. CONCLUSIONS: X-rays can leave a 'fingerprint' on structures, even at cryogenic temperatures. Serious non-isomorphism can be introduced, thus hampering multiple isomorphous replacement (MIR) and multiwavelength anomalous dispersion (MAD) phasing methods. Specific structural changes can occur before the traditional measures of radiation damage have signalled it. Care must be taken when assigning structural significance to features that might easily be radiation-damage-induced changes. It is proposed that the electron-affinic disulphide bond traps electrons that migrate over the backbone of the protein, and that the sidechains of glutamic acid and aspartic acid donate electrons to nearby electron holes and become decarboxylated successively. The different disulphide bonds in each protein show a clear order of susceptibility, which might well relate to their intrinsic stability.

Fourier Analysis↗

Green light photoplethysmography monitoring of free flaps.

BACKGROUND: Monitoring strategies have been developed to address the issue of detecting postoperative free flap ischemia in an effort to permit intervention and flap salvage. No one existing noninvasive method has been widely accepted in a clinical setting. Green light photoplethysmography (GLP) uses a diode to transmit green light into a tissue. Reflected light from hemoglobin in dermal capillary red blood cells is analyzed as light intensity along a frequency spectrum. A pure peak signal (1-2 Hz) is identified and provides a way to distinguish between perfused and nonperfused tissue. DESIGN: Prospective, blinded comparison. SUBJECTS: Sixty of 72 consecutive patients considered for free flap reconstruction were enrolled in a protocol to evaluate the efficacy of GLP. INTERVENTION: After free flap elevation, but before pedicle ligation, 120-second baseline measurements were obtained; 120-second measurements then occurred 5 minutes after the onset or release of individual venous or arterial occlusion. Signals were processed by fast Fourier transfer; a mean alternating current-direct current (AC/ DC) ratio was cultivated for each signal. All data were analyzed in a blinded fashion. RESULTS: The AC/DC ratio of GLP was statistically significant across all flap perfusion states (P<.001). Each condition resulted in a unique GLP signal within 5 minutes of manipulation of each vessel. CONCLUSIONS: Green light photoplethysmography with AC/DC ratio analysis provides a rapid, precise method with which to determine flap ischemia and can differentiate venous compromised and arterial compromised flaps almost immediately after the onset of an ischemic insult. It may provide a clinically useful tool for postoperative free flap monitoring.

Fourier Analysis↗