Abstract

The accuracy with which graphical elements are judged was assessed in a psychophysical task that parallels the real-life use of graphs. The task is a variant of the Metfessel-Comrey constant-sum method, and an associated model based on Stevens's law is proposed. The stimuli were horizontal and vertical lines, bars, pie and disk slices, cylinders, boxes, and table entries (numbers). Stevens's law exponents were near unity for numbers and 1-dimensional elements but were also close to 1 for elements possessing 2 or 3 apparent dimensions--subjects accommodate extraneous dimensions that do not carry variation, changing the effective dimensionality of the stimulus. Judgment errors were small, with numbers yielding the best performance; elements such as bars and pie slices were judged almost as accurately; disk elements were judged least accurately, but the magnitude of the errors was not large.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

I Spence. 1990. Visual psychophysics of simple graphical elements.. https://doi.org/10.1037/%2F0096-1523.16.4.683

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A low glycaemic index breakfast cereal preferentially prevents children's cognitive performance from declining throughout the morning.

This study investigated whether the glycaemic index (GI) of breakfast cereal differentially affects children's attention and memory. Using a balanced cross-over design, on two consecutive mornings 64 children aged 6-11 years were given a high GI cereal and a low GI cereal in a counterbalanced order. They performed a series of computerised tests of attention and memory, once prior to breakfast and three times following breakfast at hourly intervals. The results indicate that children's performance declines throughout the morning and that this decline can be significantly reduced following the intake of a low GI cereal as compared with a high GI cereal on measures of accuracy of attention (M=-6.742 and -13.510, respectively, p<0.05) and secondary memory (M=-30.675 and -47.183, respectively, p<0.05).

Attention↗

Inhibitory control test is a simple method to diagnose minimal hepatic encephalopathy and predict development of overt hepatic encephalopathy.

OBJECTIVES: To compare inhibitory control test (ICT), a simple/rapid test of attention, to a standard psychometric battery (SPT) to diagnose minimal hepatic encephalopathy (MHE) and predict development of overt hepatic encephalopathy (OHE) in cirrhotic patients. METHODS: Fifty nonalcoholic cirrhotics and 50 age/educational-status-matched controls were given ICT and SPT in the same sitting. Performance impaired beyond two standard deviations of controls was considered MHE in cirrhotics. ICT results (lure/target response and lures/person) were compared between controls and cirrhotics and within cirrhotics with/without MHE. Receiver-operating characteristic analysis was used to study ICT for MHE diagnosis. Twenty subjects were administered SPT and ICT twice to assess test-retest reliability. All cirrhotics were followed routinely for the development of OHE. RESULTS: Cirrhotics performed worse than controls on SPT and ICT. Using SPT, 39 cirrhotics had MHE. ICT was administered faster than SPT (15 vs 37 min). Cirrhotics with MHE had significantly higher lure (28%vs 3%) and lower target response (91%vs 96%) compared with those without MHE. Lure/person >5 had 90% sensitivity/specificity for MHE diagnosis. AUC for receiver-operating characteristic for lures alone was 95.8%. Lure and target responses were highly correlated (r= 0.9) between sessions showing high test-retest reliability. Five (10%) patients developed OHE on f/u of 26 +/- 10 months; all five had been diagnosed with MHE using ICT and SPT. None of the five patients with discordant results on SPT and ICT developed OHE. CONCLUSIONS: ICT has good sensitivity/specificity for MHE diagnosis, is reliable and is equivalent to SPT for predicting OHE development.

Attention↗