Search PubMedSearch

PubMed · 2139680

Computerized EEG: applications and interventions.

Abstract

The electroencephalogram (EEG) is the only functional tool for evaluating integrity of the neuron in the nonawake patient. Applications for this historic technology are expanding. Continuous EEG monitoring can identify cerebral ischemia while it is reversible, thus reducing neurological deficits and improving outcome. This article will review the physiology of cerebral blood flow (CBF) as it relates to EEG, interventions for restoring adequate CBF and areas for application of computerized EEG.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J P Lundgren. 1990. Computerized EEG: applications and interventions.. https://doi.org/10.1097/01376517-199004000-00010

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

P-selectin binding promotes the adhesion of monocytes to VCAM-1 under flow conditions.

This study examined the adhesive interaction of peripheral blood monocytes with VCAM-1 and analyzed the effect of P-selectin binding to monocytes on the adhesive interaction with VCAM-1 under flow conditions. P-selectin glycoprotein ligand-1 is expressed on most monocytes. Furthermore, most monocytes bind soluble P-selectin derived from platelets. P-selectin binding to monocytes did not alter the amount of expression of alpha4 integrin on monocytes. However, the mean channel fluorescence value for binding Cy2-conjugated soluble VCAM-1 to P-selectin-bound monocytes was slightly more than that for binding Cy2-conjugated soluble VCAM-1 to untreated monocytes. Under flow conditions, the number of P-selectin-bound monocytes bound to VCAM-1 was much higher than that of untreated monocytes bound to VCAM-1. These bindings were abolished by pretreatment of untreated monocytes and P-selectin-bound monocytes with anti-VCAM-1 mAb or anti-alpha4 integrin mAb. Furthermore, P-selectin binding to monocytes increased shear resistance and thus increased the adhesive strength of monocytes to VCAM-1. These findings indicate that P-selectin binding to monocytes enhances the adhesive interaction of monocytes with VCAM-1. It is suggested that P-selectin glycoprotein ligand-1/P-selectin interaction and alpha4 integrin/VCAM-1 interaction can act sequentially in the adhesion cascade that regulates monocyte trafficking to inflammatory and atherosclerotic lesion.

Blood Flow Velocity

Orientation and deformation of erythrocytes in flowing blood.

The effects of flow on the changes of electrical resistivity and light-scattering characteristics of blood are experimentally and theoretically discussed. Studies indicate that most erythrocytes deform and orient themselves in the flow direction when blood flows in a conduit. Such oriented blood shows anisotropic properties. Anisotropic electrical resistivity of flowing blood is measured in three rectangular directions with a measurement cell of coaxial cylindrical type. From these experimental results, the orientation and deformation of erythrocytes are discussed. The orientation ratio and the deformation are calculated using a simplified spheroidal model of an erythrocyte. Calculated results show that the fractions of erythrocytes with their short axis parallel to each direction and the equivalent axis ratio for a simplified spheroidal model change with the shear rate of flow.

Blood Flow Velocity

Caval contribution to flow in the branch pulmonary arteries of Fontan patients with a novel application of magnetic resonance presaturation pulse.

BACKGROUND: A complete understanding of fluid mechanics in Fontan physiology includes knowledge of the caval contributions to right (RPA) and left (LPA) pulmonary arterial blood flow, total systemic venous return, and relative blood flow to each lung. METHODS AND RESULTS: Ten Fontan patients underwent cine MRI. Three cine scans of the pulmonary arteries were performed: (1) no presaturation pulse, (2) a presaturation pulse labeling inferior vena cava (IVC) blood (signal void), and (3) a presaturation pulse labeling superior vena cava (SVC) blood. The relative signal decrease is proportional to the amount of blood originating from the labeled vena cava. This method was validated in a phantom. Whereas 60+/-6% of SVC blood flowed into the RPA, 67+/-12% of IVC blood flowed toward the LPA. Of the blood in the LPA and RPA, 48+/-14% and 31+/-17%, respectively, came from the IVC. IVC blood contributed 40+/-16% to total systemic venous return. The distributions of blood to each lung were nearly equal (RPA/LPA blood=0.94+/-11). CONCLUSIONS: In Fontan patients with total cavopulmonary connection, SVC blood is directed toward the RPA and IVC blood is directed toward the LPA. Although the right lung volume is larger than the left, an equal amount of blood flow went to both lungs. LPA blood is composed of equal amounts of IVC and SVC blood because IVC contribution to total systemic venous return is smaller than that of the SVC. This technique and these findings can help to evaluate design changes of the systemic venous pathway to improve Fontan hemodynamics.

Blood Flow Velocity