Search PubMed⌕ Search

PubMed · 2044130

Percutaneous lymph node biopsy.

Abstract

Advances in imaging modalities for detecting lymphadenopathy, the ease, safety, and accuracy of the tools and techniques, and the addition of refined ancillary studies for cytologic analysis will continue to increase the acceptance and use of percutaneous lymph node biopsy (PLNB) by fine-needle aspiration (FNA), especially in lymphomas.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D D Lawrence, C H Carrasco, B Fornage, N Sneige, S Wallace. Percutaneous lymph node biopsy.. https://doi.org/10.1007/bf02635532

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Multicenter evaluation of the breast lesion excision system, a percutaneous, vacuum-assisted, intact-specimen breast biopsy device.

BACKGROUND: Percutaneous, vacuum-assisted, large-gauge core needle biopsy (VACNB) provides an alternative to open surgical biopsy as an initial diagnostic tool for breast lesions, yet rates of underestimating malignant diagnoses remain sufficiently high to warrant surgical biopsy in some cases. The current study was performed to determine if the Breast Lesion Excision System (BLES) provides a feasible alternative to VACNB. METHODS: A retrospective review was conducted of 742 consecutive mammographic lesions with microcalcifications classified as Breast Imaging Reporting and Data System (BIRADS) IV or V that had stereotactic percutaneous biopsy using BLES. Initial diagnoses obtained from the histopathologic examination of tissues retrieved at biopsy were compared with the histopathologic examination of tissues received from surgical excision or lumpectomy. Underestimation rates for atypical ductal hyperplasia (ADH) and ductal carcinoma in situ (DCIS) were recorded if open surgical biopsy revealed DCIS or invasive cancer, and invasive cancer, respectively. RESULTS: Of the 742 breast lesions, 34 displayed ADH upon biopsy with the BLES device. Two patients did not receive open surgical biopsy. Of the 32 patients who had open surgical excision, 3 (9.4%) had DCIS or invasive cancer. There were 119 diagnoses of DCIS upon biopsy with the BLES device. Four patients did not receive open surgical biopsy. Of the 115 patients who had open surgical excision, 6 (5.2%) had invasive cancer. CONCLUSIONS: Breast biopsy can be performed accurately using the BLES device. Compared with VACNB, it does not alter the need for surgical excision in women diagnosed with ADH or DCIS at core biopsy.

Biopsy, Needle↗

Post-mortem tissue sampling using computed tomography guidance.

PURPOSE: Currently, in forensic medicine cross-sectional imaging gains recognition and a wide use as a non-invasive examination approach. Today, computed tomography (CT) or magnetic resonance imaging that are available for patients are unable to provide tissue information on the cellular level in a non-invasive manner and also diatom detection, DNA, bacteriological, chemical toxicological and other specific tissue analyses are impossible using radiology. We hypothesised that post-mortem minimally invasive tissue sampling using needle biopsies under CT guidance might significantly enhance the potential of virtual autopsy. The purpose of this study was to test the use of a clinically approved biopsy needle for minimally invasive post-mortem sampling of tissue specimens under CT guidance. MATERIAL AND METHODS: ACN III biopsy core needles 14 gauge x 160 mm with automatic pistol device were used on three bodies dedicated to research from the local anatomical institute. Tissue probes from the brain, heart, lung, liver, spleen, kidney and muscle tissue were obtained under CT fluoroscopy. RESULTS: CT fluoroscopy enabled accurate placement of the needle within the organs and tissues. The needles allowed for sampling of tissue probes with a mean width of 1.7 mm (range 1.2-2 mm) and the maximal length of 20 mm at all locations. The obtained tissue specimens were of sufficient size and adequate quality for histological analysis. CONCLUSION: Our results indicate that, similar to the clinical experience but in many more organs, the tissue specimens obtained using the clinically approved biopsy needle are of a sufficient size and adequate quality for a histological examination. We suggest that post-mortem biopsy using the ACN III needle under CT guidance may become a reliable method for targeted sampling of tissue probes of the body.

Biopsy, Needle↗

T1c prostate cancer detection rate and pathologic characteristics: comparison between patients with serum prostate-specific antigen range of 3.0 to 4.0 ng/mL and 4.1 to 10.0 ng/mL in Korean population.

OBJECTIVES: To prospectively evaluate the Stage T1c prostate cancer detection rate and pathologic characteristics of patients with a serum prostate-specific antigen (PSA) level of 3.0 to 4.0 ng/mL and compare this with the rate of patients who had a PSA level of 4.1 to 10.0 ng/mL. METHODS: We analyzed the data of patients who had PSA levels of 3.0 to 10.0 ng/mL, benign findings on digital rectal examination, and no specific lesion identified on transrectal ultrasonography. The clinical characteristics, cancer detection rate, and pathologic findings of the biopsy and prostatectomy specimen were compared between the low (3.0 to 4.0 ng/mL) and intermediate (4.1 to 10.0 ng/mL) PSA groups. RESULTS: A total of 450 patients met our criteria. Of these 450 patients, 85 and 365 had a low or an intermediate PSA level, respectively. Prostate cancer was diagnosed in 26% of the low and 19% of the intermediate PSA group. No significant difference was found between the two groups in the pathologic biopsy findings, including the mean Gleason score and percentage of patients with a Gleason score of 7 or more. The pathologic findings of the prostatectomy specimens also showed no significant differences between the two groups, including the mean Gleason score, pathologic stage, and percentage of insignificant prostate cancer. CONCLUSIONS: No statistically significant difference was found in the incidence of Stage T1c prostate cancer or pathologic characteristics in comparison between the low and intermediate PSA groups. These results suggest that a lower PSA cutoff should be considered as an indication for prostate biopsy in the Korean population.

Biopsy, Needle↗