Search PubMedSearch

PubMed · 2043462

Ultrafast imaging using gradient echoes.

Abstract

Ultrafast magnetic resonance (MR) imaging techniques can reduce scan times to less than 1 s. The rapid acquisition minimizes motion artifacts that have plagued MR studies of the heart and abdomen, and facilitates dynamic studies to observe physiological function. We first discuss fast gradient-echo methods, including various spoiled and steady-state gradient-echo techniques. Ultrafast methods are then considered, with the focus on turbo-fast low-angle shot (FLASH) (also known as snapshot or subsecond FLASH) imaging. Although turbo-FLASH is a subset of gradient echo methods, there are several distinguishing features. For instance, with T1- or T2-weighted turbo-FLASH, the magnetization never reaches a steady state, so that the phase encode order becomes an important imaging parameter. Furthermore, image contrast is obtained by adjusting the magnetization preparation module, which is independent of the data acquisition module that follows. The signal behavior and strategies for contrast optimization are discussed. Potential clinical applications, including perfusion imaging, cardiac cine, breath-hold abdominal imaging, angiography, diffusion imaging, and three-dimensional studies, are explored.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D Chien, R R Edelman. 1991. Ultrafast imaging using gradient echoes.. https://pubmed.ncbi.nlm.nih.gov/2043462/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

"Hidden" sequence periodicities and protein architecture.

I demonstrate the existence in protein domain sequences of sets of statistically significant periodic signals, characteristic of the architectures of those domains. It is shown that, although the frequencies of the signals characteristic of a particular architecture have definite wave numbers, they can occur in any physical property. The characteristic signals define sequence units, which may correspond to specific structural features. Study of signals in different architectures suggests that symmetric structures are characterized by sets of sequence signals, which are members of harmonic series and which therefore impose commensurate periodicities on the structure. Asymmetric structures are characterized by mutually incommensurate sets of sequence signals. It is pointed out that, although these periodic sequence units can be very short, their existence is a property of the entire sequence.

Fourier Analysis

Formalistic description of multislice calculation method.

This paper presents a formalistic description of the multislice method. The effects of the number of beams, the number of Fourier components for the projected potential used for the phase grating, the number of the iterations and the slice thickness on multislice calculations are discussed qualitatively. The phenomenon of "leaking" of the wave function to higher order reflections in reciprocal space in a multislice calculation is also discussed. The relationship between the number of Fourier components of the projected potential and the number of beams used for the wave function in reciprocal space is discussed. Additionally, the difference between the eigenvalue method and the multislice method is introduced. The difference between the use of the Fourier transformation vs. the convolution in reciprocal space on multislice calculations is also discussed. Multislice computer simulations were carried out using the commercial program Cerius2 for rutile TiO2. Calculated results are compared with the results of other programs reported in the literature. The effect of slice thickness of the multislice calculation is also shown.

Fourier Analysis

Gradient characterization using a Fourier-transform technique.

This paper describes a technique for characterizing the gradient subsystem of a magnetic resonance (MR) system. The technique uses a Fourier-transform analysis to directly measure the k-space trajectory produced by an arbitrary gradient waveform. In addition, the method can be easily extended to multiple dimensions and can be adapted to measuring residual gradient effects such as eddy currents. Several examples of gradient waveform and eddy-current measurements are presented. Also, it is demonstrated how the eddy-current measurements can be parameterized with an impulse-response formalism for later use in system tuning. When compared to a peak-fitting analysis, this technique provides a more direct extraction of the k-space measurements, which reduces the possibility of analysis error. This approach also has several advantages as compared to the conventional eddy-current measurement technique, including the ability to measure very short time constant effects.

Fourier Analysis