Positioning lasers used in radiotherapy generally require little adjustment. When required, this is easy to do for sidelights, but can be difficult and time consuming for ceiling mounted lasers. For this purpose, we have modified a commercial positioning laser by incorporating a device for rotating the alignment adjustment screws. This device is driven by a pair of motors remotely controlled through a cable. Two units have been built and installed. In practice, experience with these drive units has shown that it is now easier to adjust the ceiling lasers than the sidelights. Adjustment sensitivity in both units is considerably better than 1 mm, so there is little problem aligning the laser quickly and accurately.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P J Biggs, J Beatty, J Capalucci, M Russell. 1991. Remotely controlled positioning lasers.. https://doi.org/10.1016/0958-3947(91)90070-i

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Changing chairs: anticipating problems in prescribing wheelchairs.

PURPOSE: This article presents a framework for prescribing, ordering, and adapting a new wheelchair, focusing on individual, environmental and wheelchair factors that must be taken into consideration to ensure optimal function. METHOD: A review and analysis was conducted of all factors relevant to the transition to a new wheelchair. Without appropriate planning and implementation, this transition can result in unnecessary expenses, duplication of effort, and possibly even injury to the user and abandonment of the wheelchair. RESULTS: Recommendations are provided to manufacturers, therapists, technicians, users, insurers and physicians, who must work together throughout this process. To the extent feasible, the authors suggest that major changes from the previous wheelchair should be avoided, particularly for people with substantial functional limitations. Therapists and technicians must measure the user accurately, and anticipate those factors that can impede a smooth transition. Insurers and other payors must recognize that changing wheelchairs will often require substantial professional assistance, including several fittings to adjust the new chair to the needs of the user. CONCLUSION: Additional research and case reporting on outcomes of adjusting to a new wheelchair appear warranted.

Equipment Design↗

Current status of mechanical computed tomography in cardiac imaging.

Mechanical computed tomography (CT) scanners have undergone significant improvements in their ability to perform cardiac imaging. Previously limited by cardiac motion artifacts and slow acquisition speeds, newer-generation scanners are able to obtain multiple slices with a temporal resolution of <100 msec, minimizing motion artifacts to levels comparable to electron-beam computed tomography (EBCT). This is done using various approaches, including (1) prospective and retrospective electrocardiographic gating, (2) multislice detectors, and (3) partial and segmented reconstruction algorithms. The major CT manufacturers are putting significant resources into protocol optimization and cardiac applications development, including coronary calcium quantification, functional analysis, and coronary CT angiography. Given the rapid pace of development, higher in-plane and z-axis spatial resolution, and superior signal-to-noise ratio of mechanical scanners, it is evident that they will be capable of performing cardiac imaging with a quality approaching or possibly surpassing that of existing EBCT scanners. This article summarizes the current status of mechanical CT scanners in cardiac imaging.

Equipment Design↗