Search PubMed⌕ Search

PubMed · 2022962

Electrophrenic ventilation: a different perspective.

Abstract

Since 1972, radio-frequency electrophrenic nerve pacing (EPP) has been an option for assisting the ventilation of patients with chronic paralytic respiratory insufficiency. Most of the medical literature has been favorable regarding its continued application. We reviewed the literature to determine how "successful" application of EPP was defined. Our studies indicated that long-term follow-up of EPP patients has been generally inadequate with little emphasis placed on incidence and severity of complications. There was no standardization in defining successful experiences with EPP. Upper airway instability during pacing, lack of internal pacemaker alarms, and the risk of sudden pacemaker failure necessitate permanent tracheostomy in the great majority of patients but complications of the presence of a tracheostomy were not considered in evaluating the desirability of EPP. Some EPP patients became independent of any ventilatory support thus benefiting minimally from the time commitment, effort, and extreme expense needed for EPP placement and training. We conclude that EPP is a valid option for the properly screened patient but that expense, failure rate, morbidity and mortality remain excessive and that alternative methods of ventilatory support should be explored.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J R Bach, K O'Connor. 1991. Electrophrenic ventilation: a different perspective.. https://doi.org/10.1080/01952307.1991.11735829

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Tumor and normal tissue motion in the thorax during respiration: Analysis of volumetric and positional variations using 4D CT.

PURPOSE: To investigate temporospatial variations of tumor and normal tissue during respiration in lung cancer patients. METHODS AND MATERIALS: In 14 patients, gross tumor volume (GTV) and normal tissue structures were manually contoured on four-dimensional computed tomography (4D-CT) scans. Structures were evaluated for volume changes, centroid (center of mass) motion, and phase dependence of variations relative to inspiration. Only volumetrically complete structures were used for analysis (lung in 2, heart in 8, all other structures in >10 patients). RESULTS: During respiration, the magnitude of contoured volumes varied up to 62.5% for GTVs, 25.5% for lungs, and 12.6% for hearts. The range of maximum three-dimensional centroid movement for individual patients was 1.3-24.0 mm for GTV, 2.4-7.9 mm for heart, 5.2-12.0 mm for lungs, 0.3-5.5 mm for skin markers, 2.9-10.0 mm for trachea, and 6.6-21.7 mm for diaphragm. During respiration, the centroid positions of normal structures varied relative to the centroid position of the respective GTV by 1.5-8.1 mm for heart, 2.9-9.3 mm for lungs, 1.2-9.2 mm for skin markers, 0.9-7.1 mm for trachea, and 2.7-16.4 mm for diaphragm. CONCLUSION: Using 4D-CT, volumetric changes, positional alterations as well as changes in the position of contoured structures relative to the GTV were observed with large variations between individual patients. Although the interpretation of 4D-CT data has considerable uncertainty because of 4D-CT artifacts, observer variations, and the limited acquisition time, the findings might have a significant impact on treatment planning.

Diaphragm↗

Brief review: Neuromuscular monitoring: an update for the clinician.

PURPOSE: To review established techniques and to provide an update on new methods for clinical monitoring of neuromuscular function relevant to anesthesia. SOURCE: A PubMed search of relevant article for the period 1985-2005 was undertaken, and bibliographies were scanned for additional sources. PRINCIPAL FINDINGS: There is no substitute for objective neuromuscular monitoring; for research purposes, mechanomyography (MMG) is the gold standard; however, the most versatile method in the clinical setting is acceleromyography since it can be applied at various muscles and has a long track record of clinical utility. Kinemyography is valid to monitor recovery of neuromuscular transmission at the adductor pollicis muscle (AP), whereas phonomyography is easy to apply to various muscles and shows promising agreement with MMG. Monitoring of the corrugator supercilii muscle (CS) may be used to determine the earliest time for tracheal intubation as it reflects laryngeal relaxation better than monitoring at the AP. Recovery of neuromuscular transmission is best monitored at the AP, since it is the last muscle to recover from neuromuscular blockade (NMB). If train-of-four (TOF) stimulation is used, a TOF-ratio > 0.9 should be the target before awakening the patient. If surgery or the type of anesthesia necessitates NMB of a certain degree, e.g., TOF-ratio = 0.25, monitoring of muscles which best reflect the degree of NMB at the surgical site is preferable. CONCLUSION: Objective methods should be used to monitor neuromuscular function in clinical anesthesia. Acceleromyography offers the best compromise with respect to ease of use, practicality, versatility, precision and applicability at various muscles. The CS is the optimal muscle to determine the earliest time for intubation, e.g., for rapid sequence induction.

Diaphragm↗