Noise correlation.

Abstract

Calculations and experiments that provide support for our previously stated theorem are presented: If two coils simultaneously receiving magnetic resonance signals from the same anatomic region exhibit zero mutual inductance, there can be no correlation of the noise. It is shown that correlation does not exist even in the presence of mutual inductance unless the two signal paths have amplifiers prior to signal combination. It is further found that in the presence of mutual inductance with ideal amplifiers (0 dB noise figure) in the two signal paths, there is no correlation of noise. In order to satisfy the condition of zero mutual inductance, it may be necessary to employ a decoupling circuit external to the body. A novel coil assembly, which was used in the experiments, places a single-turn surface coil in the median plane between the two loops of a counter rotating current coil. The signal-to-noise ratio can be improved by combining signals. This is in analogy to quadrature receiving coils, where the mutual inductance is zero because vector reception fields are perpendicular. In the present geometry, vector reception fields are collinear, but are parallel and antiparallel on the two sides of the coil assembly, resulting in zero mutual inductance.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

A Jesmanowicz, J S Hyde, W Froncisz, J B Kneeland. 1991. Noise correlation.. https://doi.org/10.1002/mrm.1910200105

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A single supply biopotential amplifier.

A biopotential amplifier for single supply operation is presented. It uses a Driven Right Leg Circuit (DRL) to drive the patient's body to a DC common mode voltage, centering biopotential signals with respect to the amplifier's input voltage range. This scheme ensures proper range operation when a single power supply is used. The circuit described is especially suited for low consumption, battery-powered applications, requiring a single battery and avoiding switching voltage inverters to achieve dual supplies. The generic circuit is described and, as an example, a biopotential amplifier with a gain of 60 dB and a DC input range of +/-200 mV was implemented using low power operational amplifiers. A Common Mode Rejection Ratio (CMRR) of 126 dB at 50 Hz was achieved without trimming.

Amplifiers, Electronic↗

Development of panel loudspeaker system: design, evaluation and enhancement.

Panel speakers are investigated in terms of structural vibration and acoustic radiation. A panel speaker primarily consists of a panel and an inertia exciter. Contrary to conventional speakers, flexural resonance is encouraged such that the panel vibrates as randomly as possible. Simulation tools are developed to facilitate system integration of panel speakers. In particular, electro-mechanical analogy, finite element analysis, and fast Fourier transform are employed to predict panel vibration and the acoustic radiation. Design procedures are also summarized. In order to compare the panel speakers with the conventional speakers, experimental investigations were undertaken to evaluate frequency response, directional response, sensitivity, efficiency, and harmonic distortion of both speakers. The results revealed that the panel speakers suffered from a problem of sensitivity and efficiency. To alleviate the problem, a woofer using electronic compensation based on H2 model matching principle is utilized to supplement the bass response. As indicated in the result, significant improvement over the panel speaker alone was achieved by using the combined panel-woofer system.

Amplifiers, Electronic↗

A broadband phased-array system for direct phosphorus and sodium metabolic MRI on a clinical scanner.

Despite their proven gains in signal-to-noise ratio and field-of-view for routine clinical MRI, phased-array detection systems are currently unavailable for nuclei other than protons (1H). A broadband phased-array system was designed and built to convert the 1H transmitter signal to the non-1H frequency for excitation and to convert non-1H phased-array MRI signals to the 1H frequency for presentation to the narrowband 1H receivers of a clinical whole-body 1.5 T MRI system. With this system, the scanner operates at the 1H frequency, whereas phased-array MRI occurs at the frequency of the other nucleus. Pulse sequences were developed for direct phased-array sodium (23Na) and phosphorus (31P) MRI of high-energy phosphates using chemical selective imaging, thereby avoiding the complex processing and reconstruction required for phased-array magnetic resonance spectroscopy data. Flexible 4-channel 31P and 23Na phased-arrays were built and the entire system tested in phantom and human studies. The array produced a signal-to-noise ratio improvement of 20% relative to the best-positioned single coil, but gains of 300-400% were realized in many voxels located outside the effective field-of-view of the single coil. Cardiac phosphorus and sodium MRI were obtained in 6-13 min with 16 and 0.5 mL resolution, respectively. Lower resolution human cardiac 23Na MRI were obtained in as little as 4 sec. The system provides a practical approach to realizing the advantages of phased-arrays for nuclei other than 1H, and imaging metabolites directly.

Amplifiers, Electronic↗