Better speech recognition with cochlear implants.

Abstract

HIGH levels of speech recognition have been achieved with a new sound processing strategy for multielectrode cochlear implants. A cochlear implant system consists of one or more implanted electrodes for direct electrical activation of the auditory nerve, an external speech processor that transforms a microphone input into stimuli for each electrode, and a transcutaneous (rf-link) or percutaneous (direct) connection between the processor and the electrodes. We report here the comparison of the new strategy and a standard clinical processor. The standard compressed analogue (CA) processor presented analogue waveforms simultaneously to all electrodes, whereas the new continuous interleaved sampling (CIS) strategy presented brief pulses to each electrode in a nonoverlapping sequence. Seven experienced implant users, selected for their excellent performance with the CA processor, participated as subjects. The new strategy produced large improvements in the scores of speech reception tests for all subjects. These results have important implications for the treatment of deafness and for minimal representations of speech at the auditory periphery.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

B S Wilson, C C Finley, D T Lawson, R D Wolford, D K Eddington, W M Rabinowitz. 1991-07-18. Better speech recognition with cochlear implants.. https://doi.org/10.1038/352236a0

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The perceptual effects of interphase gap duration in cochlear implant stimulation.

The most common current pulse shape used for cochlear implants is a biphasic rectangular pulse. The interphase gap (IPG) is the duration of the zero-current portion which lies between the two phases. It is known from single-nerve studies in animals that, as the IPG decreases, the biphasic pulse becomes less efficient in activating the nerve cell. Thus, it can be predicted that stimulation using smaller IPGs will necessitate the use of higher currents to maintain the loudness required by the cochlear implantee. The development of contemporary processing schemes commonly involves the maximization of the rate parameter, and to achieve this in sequential pulsatile stimulation, the IPG as well as the pulse phase duration must be minimized. This experiment investigated the effect of IPG on loudness in eight cochlear implantees who use the CI24 implant manufactured by Cochlear Ltd. An exponential increase in current level was required to maintain equal loudness when IPG is reduced from 100 to 45 and 8.4 micros. The effect of IPG was greater at lower levels, was greater for shorter pulse durations (26 micros compared to 52 micros), and was not significantly different for the rates (1 kHz or 4 kHz) tested.

Cochlear Implants↗