Search PubMed⌕ Search

PubMed · 1806109

Differential pathlength factor for diffuse photon scattering through tissue by a pulse-response method.

Abstract

Although near-infrared (NIR) spectroscopy may one day provide a noninvasive measurement of oxidative metabolism in tissue, the method cannot be fully quantitative until the mean pathlength traveled by photons between reference and output detectors (i.e, optrodes) is known. In NIR spectroscopy, photons are transported primarily by diffuse scattering, and their mean pathlength can be expressed by a differential path factor (DPF) whose value is greater than the interoptrode distance. Beginning with a P1 diffusion approximation of the Boltzmann equation, one-dimensional photon currents originating from plane, line, and point photon sources were analyzed. DPF was formulated from the attenuation of light intensity generated by constant sources, and an equation for the mean time of flight of photons between reference and output optrodes, delta tau, was derived for arbitrarily pulsed sources. The results indicate that (1) the attenuation of light in tissue does not, in general, vary with interoptrode distance in the manner predicted by Beer's law; (2) the relationship between DPF and interoptrode distance is nonlinear and geometry-dependent; and (3) in spite of these nonidealities, DPF is equal to the product of delta tau and the speed of light.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J S Ultman, C A Piantadosi. 1991. Differential pathlength factor for diffuse photon scattering through tissue by a pulse-response method.. https://doi.org/10.1016/0025-5564(91)90072-q

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Targeted profiling: quantitative analysis of 1H NMR metabolomics data.

Extracting meaningful information from complex spectroscopic data of metabolite mixtures is an area of active research in the emerging field of "metabolomics", which combines metabolism, spectroscopy, and multivariate statistical analysis (pattern recognition) methods. Chemometric analysis and comparison of 1H NMR1 spectra is commonly hampered by intersample peak position and line width variation due to matrix effects (pH, ionic strength, etc.). Here a novel method for mixture analysis is presented, defined as "targeted profiling". Individual NMR resonances of interest are mathematically modeled from pure compound spectra. This database is then interrogated to identify and quantify metabolites in complex spectra of mixtures, such as biofluids. The technique is validated against a traditional "spectral binning" analysis on the basis of sensitivity to water suppression (presaturation, NOESY-presaturation, WET, and CPMG), relaxation effects, and NMR spectral acquisition times (3, 4, 5, and 6 s/scan) using PCA pattern recognition analysis. In addition, a quantitative validation is performed against various metabolites at physiological concentrations (9 microM-8 mM). "Targeted profiling" is highly stable in PCA-based pattern recognition, insensitive to water suppression, relaxation times (within the ranges examined), and scaling factors; hence, direct comparison of data acquired under varying conditions is made possible. In particular, analysis of metabolites at low concentration and overlapping regions are well suited to this analysis. We discuss how targeted profiling can be applied for mixture analysis and examine the effect of various acquisition parameters on the accuracy of quantification.

Metabolism↗