A linearized DC lamp controller.

Abstract

The design of a simple and inexpensive battery powered lamp controller for microscope lamps commonly used in patch clamp and other biophysical studies is described. The circuit linearizes the normally exponential voltage-intensity curve of standard 12-V lamps by using an operational amplifier to provide feedback to the drain of a power MOSFET. When the unit is turned off, a charging circuit recharges the battery at a constant potential until the battery voltage reaches a preset level. The charging voltage is then reduced to balance the self-discharge rate of the battery.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J A Galbraith. 1991. A linearized DC lamp controller.. https://doi.org/10.1016/0165-0270(91)90098-k

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Design and evaluation of shielded gradient coils.

Techniques are described for the design of shielded gradient coils for superconducting MRI systems. These design methods are suited for constructing the most efficient gradient coil that meets a specified homogeneity requirement. Tradeoffs in coil design of efficiency with coil size and gap size are discussed. Residual eddy currents from coils constructed with a finite number of wires are calculated and give guidelines for the construction of efficient, whole-body gradient coils.

Amplifiers, Electronic

A piezoelectric respiratory monitor for in vivo NMR.

This report describes a simple electronic device employing a piezoelectric element which serves as a sensitive detector of motion. The device is useful as a monitor of respiratory motion for nuclear magnetic resonance animal experiments in vivo. It can also provide a trigger pulse for respiratory gating experiments.

Amplifiers, Electronic

Correction for liquid junction potentials in patch clamp experiments.

This chapter describes corrections that have to be applied to measured membrane potentials in patch clamp experiments. Some of them [Eqs. (1)-(3)] are required regardless of the nature of the reference electrode (in the Ringer's solution bath) whenever the pipette-filling solution is different from the bath solution. They represent the liquid junction potentials that are present at the pipette tip before patch formation. In addition, corrections have to be applied when the bath solution is being changed during a measurement (i.e., after seal formation). In that case the following rules apply. (1) The new solution should never get into contact with the bare silver/silver chloride wire of the reference electrode. This requirement is best met by using a salt bridge. (2) The "best" salt bridge is a 3 M KCl bridge with an abrupt KCl-bath fluid boundary at its tip (see above). This bridge does not require any additional potential corrections, but it may lead to KCl poisoning of the bath or become contaminated by solutions used previously. (3) Local solution changes (microperfusion by puffer pipette, U tool or sewer pipe arrangements) as well as recessed KCl bridges require additional corrections, which (together with the simple liquid junction potential correction) are approximately given by Eqs. (6)-(8). It should be stressed that all equations given here represent approximate corrections, since liquid junction potentials are thermodynamically ill-defined. This is particularly relevant for Eqs. (6) and (7) where the sum of two liquid junction potentials appears.

Amplifiers, Electronic