Search PubMed⌕ Search

PubMed · 1782483

Fibrin glue.

Abstract

Fibrin glue is a topical biological adhesive, the effect of which imitates the final stages of coagulation. The glue consists of a solution of concentrated human fibrinogen which is activated by the addition of bovine thrombin and calcium chloride. The resultant clot aids haemostasis and tissue sealing and is completely absorbed during wound healing without foreign body reaction or extensive fibrosis. The fibrinogen component of fibrin glue can be produced from fresh frozen plasma obtained from single unit donations thereby reducing the risks of transfusion transmitted infections encountered by exposure to pools from large numbers of donors. Methods involving precipitation of fibrinogen by cryoprecipitation, polyethylene glycol or ammonium sulphate have been described and evaluated. The risk of transmission of infection can be further reduced by using plasma from 'accredited donors' who are plasma donors regularly tested for ALT and markers of viral infection or by use of fibrinogen prepared in advance of surgery from autologous blood. The second component, a mixture of thrombin and CaCl2, is quantitatively and qualitatively well defined and commercially available (Armour Pharmaceutical Co., Thrombinar (bovine thrombin]. Thrombin is applied to the operation site simultaneously and in equal volume to the fibrinogen but from a separate syringe. In the UK a commercial heat treated fibrin glue prepared from pooled plasma is available on a doctor/named patient basis (Tisseel, Immuno, Vienna). The haemostatic and adhesive properties of fibrin glue can be employed in virtually every surgical specialty. The usefulness of the glue is particularly well documented in the fields of cardiovascular surgery, ENT and neurosurgery.(ABSTRACT TRUNCATED AT 250 WORDS)

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Brennan. 1991. Fibrin glue.. https://doi.org/10.1016/0268-960x(91)90015-5

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Molecular characterization of an Italian patient with plasminogen deficiency and ligneous conjunctivitis.

Plasminogen deficiency is a rare disease characterized by ligneous conjunctivitis and infections. We observed a 3-year-old Italian boy presenting ligneous conjunctivitis and low plasma levels of plasminogen. Twenty-three different mutations on the PLG gene have been reported to date, but mutation analysis had been troublesome for the presence of highly homologous genes. The aim of the study was to identify the underlying mutation avoiding coamplification of unwanted genetic materials using a long polymerase chain reaction strategy, instead of the previously reported subcloning methods. By this simple strategy the complete sequence analysis of PLG gene was performed, and a previously reported missense homozygous mutation (K19E) was identified.

Blood Coagulation Disorders↗

Diagnosis of early coagulation abnormalities in trauma patients by rotation thrombelastography.

BACKGROUND: Reagent-supported thromboelastometry with the rotation thrombelastography (e.g. ROTEM) is a whole blood assay that evaluates the visco-elastic properties during blood clot formation and clot lysis. A hemostatic monitor capable of rapid and accurate detection of clinical coagulopathy within the resuscitation room could improve management of bleeding after trauma. OBJECTIVES: The goals of this study were to establish whether ROTEM correlated with standard coagulation parameters to rapidly detect bleeding disorders and whether it can help to guide transfusion. METHODS: Ninety trauma patients were included in the study. At admission, standard coagulation assays were performed and ROTEM parameters such as clot formation time (CFT) and clot amplitude (CA) were obtained at 15 min (CA(15)) with two activated tests (INTEM, EXTEM) and at 10 min (CA(10)) with a test analyzing specifically the fibrin component of coagulation (FIBTEM). RESULTS: Trauma induced significant modifications of coagulation as assessed by standard assays and ROTEM. A significant correlation was found between prothrombin time (PT) and CA(15)-EXTEM (r = 0.66, P < 0.0001), between activated partial thromboplastin time and CFT-INTEM (r = 0.91, P < 0.0001), between fibrinogen level and CA(10)-FIBTEM (r = 0.85, P < 0.0001), and between platelet count and CA(15)-INTEM (r = 0.57, P < 0.0001). A cutoff value of CA(15)-EXTEM at 32 mm and CA(10)-FIBTEM at 5 mm presented a good sensitivity (87% and 91%) and specificity (100% and 85%) to detect a PT > 1.5 of control value and a fibrinogen less than 1 g L(-1), respectively. CONCLUSIONS: ROTEM is a point-of-care device that rapidly detects systemic changes of in vivo coagulation in trauma patients, and it might be a helpful device in guiding transfusion.

Blood Coagulation Disorders↗