Long-term structural changes in pH-sensitive hydrogels.

Abstract

The long-term swelling properties of lightly cross-linked copolymer hydrogels consisting of methyl methacrylate (MMA) and N,N-dimethylaminoethyl methacrylamide (DMAA) were studied as a function of pH at 25 degrees C and 37 degrees C. In acidic pH regions, the swelling equilibria were found to be stable over 200 d. In alkaline pH environments, however, the 'equilibrium' swelling increases slowly with time. Gas chromatography of the supernatant shows that substantial methanol is produced, along with trace amounts of N,N-dimethylethylene diamine. Thus, the primary mechanism underlying the structural changes appears to be hydrolysis of ester groups in the MMA side-chains, with a much smaller contribution due to amidolysis of the DMAA side-chains. The implications of these structural changes for the application of this hydrogel, as well as other related hydrogels as long-term implantable biomaterials, are discussed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C P De Moor, L Doh, R A Siegel. 1991. Long-term structural changes in pH-sensitive hydrogels.. https://doi.org/10.1016/0142-9612(91)90071-h

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Three-dimensional visualization and measurement of conformal dose distributions using magnetic resonance imaging of BANG polymer gel dosimeters.

PURPOSE/OBJECTIVE: The measurement of complex dose distributions (those created by irradiation through multiple beams, multiple sources, or multiple source dwell positions) requires a dosimeter that can integrate the dose during a complete treatment. Integrating dosimeter devices generally are capable of measuring only dose at a point (ion chamber, diode, TLD) or in a plane (film). With increasing use of conformal dose distributions requiring shaped, noncoplanar beams, there will be an increased requirement for a dosimeter that can record and display a 3D dose distribution. The use of a 3D dosimeter will be required to confirm the accuracy of treatment plans produced by the current generation of 3D treatment-planning computers. METHODS AND MATERIALS: The use of a Fricke-infused gel and magnetic resonance imaging (MRI) to demonstrate the localization of stereotactic beams has been demonstrated (11). The recently developed BANG polymer gel dosimetry system (MGS Research, Inc., Guilford, CT), based on radiation-induced chain polymerization of acrylic monomers dispersed in a tissue-equivalent gel, surpasses the Fricke-gel method by providing accurate, quantitative dose distribution data that do not deteriorate with time (6, 9). The improved BANG2 formulation contains 3% N,N'-methylene-bisacrylamide, 3% acrylic acid, 1% sodium hydroxide, 5% gelatin, and 88% water, where all percentages are by weight. The gel was poured into volumetric flasks, of dimensions comparable to a human head. The gels were irradiated with complex beam arrangements, similar to those used for conformal radiation therapy. Images of the gels were acquired using a Siemens 1.5T imager and a Hahn spin-echo pulse sequence (90 degrees-tau-180 degrees-tau-acquire, for different values of tau). The images were transferred via network to a Macintosh computer for which a data analysis and display program was written. The program calculates R2 maps on the basis of multiple TE images, using a monoexponential nonlinear least-squares fit based on the Levenberg-Marquardt algorithm. The program also creates a dose-to-R2 calibration function by fitting a polynomial to a set of dose and R2 data points, obtained from gels irradiated in test tubes to known doses. This function can then be applied to any other R2 map, so that a dose map can be computed and displayed. RESULTS: Through exposure to known doses of radiation, the gel has been shown to respond linearly with dose in the range of 0 to 10 Gy, and its response is independent of the beam energy or modality. Dose distributions have been imaged in orthogonal planes, and can be displayed in a convenient form for comparison with isodose plans. The response of the gel is stable; the gel can be irradiated at any time after its manufacture, and imaging can be conducted any time following a brief interval after irradiation. CONCLUSION: The polymer gel dosimeter has been shown to be a valuable device for displaying three-dimensional dose distributions. The imaged dose distribution can be compared easily with calculated dose distributions, to validate a treatment planning system. In the future, gels may be prepared in anthropomorphic phantoms, to confirm unique patient dose distributions.

Gels

NMR and the mobility of water in polysaccharide gels.

An analysis of the possible modes of motion of water molecules in polysaccharide gels indicates that the interpretation of NMR results does not require the supposition of a class of 'bound water' with highly perturbed motional states. There may, however, be water molecules associated with junction zones in the gels whose motions are restricted either by incorporation into the molecular secondary structure or as interstitial water in crystallites. Hydration and dehydration effects as well as the phenomenon of non-freezing water may all be explained within a framework of well understood processes. It is concluded that there is no requirement to appeal to 'bound water' to explain any of the properties of water in polysaccharide gels.

Gels

Sample-streaks and smears in immobilized pH gradient gels.

In immobilized pH gradient (IPG) gel formulations as wide as pH 4-9, encompassing neutrality and containing the pK 7.0 acrylamido buffer as one of the buffering ions, smears are directly proportional to the total amount of the pK 7.0 species. At a total level of 10 mM pK 7.0 in these gel formulations, severe smears occur not only for mildly hydrophobic proteins (e.g., recombinant alcalase and termamylase) but also for the relatively hydrophilic pI marker proteins. Streaks and smears are essentially abolished in recipes devoid of the pK 7.0 compound or in formulations containing a maximum of 3 mM of this component. Although partitioning in water/n-octanol has shown the pK 7.0 acrylamido buffer to be quite hydrophobic (P = 0.5), the occurrence of smears could be to the presence of oligomers in some commercial preparations. Even when dissolved in n-propanol, some batches of acrylamido buffers might still contain oligomers, probably formed during the synthetic step.

Gels