Search PubMed⌕ Search

PubMed · 17119795

Visual and automatic cyclic alternating pattern (CAP) scoring: inter-rater reliability study.

Abstract

The classification of short duration events in the EEG during sleep, as the A stage of the cyclic alternating pattern (CAP) is a tedious and error prone task. The number of events under normal conditions is large (several hundreds), and it is necessary to mark the limits of the events with precision, otherwise the time sensitive classification of the CAP phases (A and B) and specially the scoring of different types of A phases will be compromised. The objective of this study is to verify the feasibility of visual CAP scoring with only one channel of EEG, the evaluation of the inter-scorer agreement in a variety of recordings, and the comparison of the visual scorings with a known automatic scoring system. Sixteen hours of one channel (C4-A1 or C3-A2) of NREM sleep were extracted from eight whole night recordings in European Data Format and presented to the different scorers. The average inter-scorer agreement for all scorers is above 70%, the pair wise inter-scorer agreement found was between 69% up to 77.5%. These values are similar to what has been reported in different type studies. The automatic scoring system has similar performance of the visual scorings. The study also has shown that it is possible to classify the CAP using only one channel of EEG.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Agostinho Rosa, Gabriela Rodrigues Alves, Magneide Brito, Maria Cecília Lopes, Sérgio Tufik. 2006. Visual and automatic cyclic alternating pattern (CAP) scoring: inter-rater reliability study.. https://doi.org/10.1590/s0004-282x2006000400008

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A Kalman filter based methodology for EEG spike enhancement.

In this work, we present a methodology for spike enhancement in electroencephalographic (EEG) recordings. Our approach takes advantage of the non-stationarity nature of the EEG signal using a time-varying autoregressive model. The time-varying coefficients of autoregressive model are estimated using the Kalman filter. The results show considerable improvement in signal-to-noise ratio and significant reduction of the number of false positives.

Electroencephalography↗

Visual evoked potential in the newborn: does it have predictive value?

We reviewed studies on the predictive value of visual evoked potentials (VEPs) in the newborn. VEPs demonstrated a good correlation with neurodevelopmental outcome in full-term infants with birth asphyxia. However, their prognostic value in preterm infants is controversial. In preterm infants, most studies showed high specificities for neurodevelopmental outcome, but some studies demonstrated lower sensitivities.

Electroencephalography↗