Search PubMed⌕ Search

PubMed · 1703449

Estimating kinetic parameters for single channels with simulation. A general method that resolves the missed event problem and accounts for noise.

Abstract

Analysis of currents recorded from single channels is complicated by the limited time resolution (filtering) of the data which can prevent the detection of brief intervals. Although a number of approaches have been used to correct for the undetected intervals (missed events) when identifying kinetic models and estimating parameters, none of them provide a general method which takes into account the true effects of noise and limited time resolution. This paper presents such a method. The approach is to use simulated single-channel currents to incorporate the true effects of filtering and noise on missed events and interval durations. The simulated currents are then analyzed in a manner identical to that used to analyze the experimental currents. An iterative search process using likelihood comparison of two-dimensional dwell-time distributions obtained from the simulated and experimental single-channel currents then allows the most likely rate constants to be determined. The large errors and false solutions that can result from the more typically applied assumptions of no noise and an absolute dead time (idealized filtering) are excluded by the iterative simulation method, and the correlation information contained in the two-dimensional distributions should increase the ability to distinguish among different gating mechanisms. The iterative simulation method is generally applicable to channels which typically open to a single conductance level. For these channels the method places no restrictions on the proposed gating mechanism or the form of the predicted dwell-time distributions.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K L Magleby, D S Weiss. 1990. Estimating kinetic parameters for single channels with simulation. A general method that resolves the missed event problem and accounts for noise.. https://doi.org/10.1016/s0006-3495(90)82487-5

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Utilizing the information content in two-state trajectories.

The signal from many single-molecule experiments monitoring molecular processes, such as enzyme turnover by means of fluorescence and opening and closing of ion channel through the flux of ions, consists of a time series of stochastic "on" and "off" (or open and closed) periods, termed a two-state trajectory. This signal reflects the dynamics in the underlying multisubstate on-off kinetic scheme (KS) of the process. The determination of the underlying KS is difficult and sometimes even impossible because of the loss of information in the mapping of the multidimensional KS onto two dimensions. Here we introduce a previously undescribed procedure that efficiently and optimally relates the signal to all equivalent underlying KS. This procedure partitions the space of KS into canonical (unique) forms that can handle any KS and obtains the topology and other details of the canonical form from the data without the need for fitting. Also established are relationships between the data and the topology of the canonical form to the on-off connectivity of a KS. The suggested canonical forms constitute a powerful tool in discriminating between KS. Based on our approach, the upper bound on the information content in two-state trajectories is determined.

Ion Channel Gating↗

Voltage-dependent synchronization of gating of syringomycin E ion channels.

Antifungal lipodepsipeptide syringomycin E (SRE) forms two major conductive states in lipid bilayers: "small" and "large". Large SRE channels are cluster of several small ones, demonstrating synchronous opening and closure. To get insight into the mechanism of such synchronization we investigated how transmembrane potential, membrane surface charge, and ionic strength affect the number of small SRE channels synchronously functioning in the cluster. Here, we report that the large SRE channels can be presented as 3-8 simultaneously gating small channels. The increase in the absolute value of the transmembrane potential (from 50 to 200 mV) decreases the number of synchronously gated channels in the clusters. Voltage-dependence of channel synchronization was influenced by the ionic strength of the bathing solution, but not by membrane surface charge. We propose a mechanism for the voltage-dependent cluster behavior that involves a voltage-induced reorientation of lipid dipoles associated with the channel pores.

Ion Channel Gating↗