Optimization of self-reference thermometry using complex field estimation.

Abstract

Referenceless, or self-reference, thermometry is a technique for mapping temperature differences in the region of interest (ROI) using the baseline phase estimated by extrapolating the field in the surrounding region for estimation (RFE) and subtracting the estimated baseline from the measured field. In the present work a self-reference technique based on complex field estimation using 2D polynomials comprising complex-valued coefficients was proposed and optimized. Numerical simulations with a Gaussian-profiled phase distribution demonstrated that the ROI radius had to be 2.3-2.5 times the standard deviation (SD) of the Gaussian function in order to keep the error below 8% of the peak phase change. The area ratio between the ROI and the RFE had to be larger than 2.0 to maintain the error level. Based on the simulations, and phantom and volunteer experiments, the complex-based method with independently optimized polynomial orders for the two spatial dimensions was compared with the phase-based method using the similar-order optimization strategy. The complex-based method appeared to be useful when phase unwrapping was not removed. Otherwise, the phase-based method yielded equivalent results with less polynomial orders.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Kagayaki Kuroda, Daisuke Kokuryo, Etsuko Kumamoto, Kyohei Suzuki, Yuichiro Matsuoka, Bilgin Keserci. 2006. Optimization of self-reference thermometry using complex field estimation.. https://doi.org/10.1002/mrm.21016

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Thermographic assessment of inferior alveolar nerve injury in patients with dentofacial deformity.

PURPOSE: The purpose of this study was to evaluate the injury and recovery of the inferior alveolar nerve in orthognathic patients at 1 and 4 weeks after surgery using electronic thermography. MATERIALS AND METHODS: Twenty subjects with Class III dentofacial deformity were studied. All patients underwent bilateral sagittal split ramus osteotomy. To image the temperature of the face, 1 anteroposterior view and 1 lateral view were taken from both the right and left sides. Similar images were taken at 1 and 4 weeks after surgery. The control was the presurgical temperature of the 20 patients who showed unilateral or bilateral nerve damage after surgery. RESULTS: In the patients with unilateral nerve damage (n = 14), on the anteroposterior views, the temperatures of the mentum on the 2 sides differed by 0.64 degrees C at 1 week after surgery, and the difference decreased to 0.23 degrees C at 4 weeks after surgery. On the lateral images, the differences in temperature between the mentum areas were 0.10 degrees C at 1 week and 0.27 degrees C at 4 weeks after surgery. In the patients with bilateral nerve injury (n = 6), on the anteroposterior views, the temperatures of the mentum on the 2 sides differed by 0.20 degrees C at 1 week after surgery and 0.13 degrees C after 4 weeks. On the lateral views, the differences were 0.18 degrees C at 1 week and 0.34 degrees C at 4 weeks after surgery. Using the repeated measurement analysis method, the anteroposterior view showed statistically significant results in the patients with unilateral nerve damage. CONCLUSION: The infrared body temperature method is an objective method that can be applied as a supplemental diagnostic method for inferior alveolar nerve injury.

Body Temperature↗

The ingestible telemetric body core temperature sensor: a review of validity and exercise applications.

An ingestible telemetric temperature sensor for measuring body core temperature (Tc) was first described 45 years ago, although the method has only recently gained widespread use for exercise applications. This review aims to (1) use Bland and Altman's limits of agreement (LoA) method as a basis for quantitatively reviewing the agreement between intestinal sensor temperature (Tintestinal), oesophageal temperature (Toesophageal) and rectal temperature (Trectal) across numerous previously published validation studies; (2) review factors that may affect agreement; and (3) review the application of this technology in field-based exercise studies. The agreement between Tintestinal and Toesophageal is suggested to meet our delimitation for an acceptable level of agreement (ie, systematic bias <0.1 degrees C and 95% LoA within +/-0.4 degrees C). The agreement between Tintestinal and Trectal shows a significant systematic bias >0.1 degrees C, although the 95% LoA is acceptable. Tintestinal responds less rapidly than Toesophageal at the start or cessation of exercise or to a change in exercise intensity, but more rapidly than Trectal. When using this technology, care should be taken to ensure adequate control over sensor calibration and data correction, timing of ingestion and electromagnetic interference. The ingestible sensor has been applied successfully in numerous sport and occupational applications such as the continuous measurement of Tc in deep sea saturation divers, distance runners and soldiers undertaking sustained military training exercises. It is concluded that the ingestible telemetric temperature sensor represents a valid index of Tc and shows excellent utility for ambulatory field-based applications.

Body Temperature↗