Search PubMed⌕ Search

PubMed · 16901228

Data standards for flow cytometry.

Abstract

Flow cytometry (FCM) is an analytical tool widely used for cancer and HIV/AIDS research, and treatment, stem cell manipulation and detecting microorganisms in environmental samples. Current data standards do not capture the full scope of FCM experiments and there is a demand for software tools that can assist in the exploration and analysis of large FCM datasets. We are implementing a standardized approach to capturing, analyzing, and disseminating FCM data that will facilitate both more complex analyses and analysis of datasets that could not previously be efficiently studied. Initial work has focused on developing a community-based guideline for recording and reporting the details of FCM experiments. Open source software tools that implement this standard are being created, with an emphasis on facilitating reproducible and extensible data analyses. As well, tools for electronic collaboration will assist the integrated access and comprehension of experiments to empower users to collaborate on FCM analyses. This coordinated, joint development of bioinformatics standards and software tools for FCM data analysis has the potential to greatly facilitate both basic and clinical research--impacting a notably diverse range of medical and environmental research areas.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Josef Spidlen, Robert C Gentleman, Perry D Haaland, Morgan Langille, Nolwenn Le Meur, Michael F Ochs, Charles Schmitt, Clayton A Smith, Adam S Treister, Ryan R Brinkman. 2006. Data standards for flow cytometry.. https://doi.org/10.1089/omi.2006.10.209

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Fluorescent protein pair emit intracellular FRET signal suitable for FACS screening.

The fluorescent proteins ECFP and HcRed were shown to give an easily resolved FRET-signal when expressed as a fusion inside mammalian cells. HeLa-tat cells expressing ECFP, pHcRed, or the fusion protein pHcRed-ECFP were analyzed by flow cytometry after excitation of ECFP. Cells expressing HcRed-ECFP, or ECFP and HcRed, were mixed and FACS-sorted for FRET positive cells: HcRed-ECFP cells were greatly enriched (72 times). Next, cloned human antibodies were fused with ECFP and expressed anchored to the ER membrane. Their cognate antigens (HIV-1 gp120 or gp41) were fused to HcRed and co-expressed in the ER. An increase of 13.5+/-1.5% (mean+/-SEM) and 8.0+/-0.7% in ECFP fluorescence for the specific antibodies reacting with gp120 or gp41, respectively, was noted after photobleaching. A positive control (HcRed-ECFP) gave a 14.8+/-2.6% increase. Surprisingly, the unspecific antibody (anti-TT) showed 12.1+/-1.1% increase, possibly because overexpression in the limited ER compartment gave false FRET signals.

Cell Separation↗

Wall-yielding properties of cell walls from elongating cucumber hypocotyls in relation to the action of expansin.

The wall-yielding properties of cell walls were examined using frozen-thawed and pressed segments (FTPs) obtained from the elongation zones of cucumber hypocotyls with a newly developed programmable creep meter. The rate of wall extension characteristically changed depending on both tension and pH. By treatment of the FTPs with acid, the yield tension (y) was shifted downward and the extensibility (phi) was increased. However, the downward shift of y was greatly suppressed and the increase in phi was partly inhibited in boiled FTPs. The boiled FTPs reconstituted with expansin fully recovered the acid-induced downward y shift as well as the increase in phi. Even under the tension below y, wall extension took place pH dependently. Such extension was markedly slower (low-rate extension) than that under the tension above y (high-rate extension). At a higher concentration (8 M), urea markedly inhibited the creep ascribable to the inhibition of the acid-induced downward y shift and increase in phi. Moderate concentrations (2 M) of urea promoted wall creep pH dependently. The promotion was equivalent to a 0.5 decrease in pH. The promotion of creep by 2 M urea was observed in boiled FTPs reconstituted with expansin but not in boiled FTPs. These findings indicated that the acid-facilitated creep was controlled by y as well as in cucumber cell walls. However, y and phi might be inseparable and mutually related parameters because the curve of the stress extension rate (SER) showed a gradual change from the low-rate extension to the high-rate extension. Expansin played a role in pH-dependent regulation of both y and phi. The physiological meaning of the pH-dependent regulation of wall creep under different creep tensions is also discussed with reference to a performance chart obtained from the SER curves.

Cell Separation↗

Rapid direct determination using combined separation by prepared immunomagnetic and flow cytometry of Flavobacterium psychrophilum.

Flavobacterium psychrophilum, the causative agent of bacterial cold-water disease (BCWD), was originally isolated from coho salmon Oncorhychus kisutch in the USA. Bacterial cold-water disease has since been spreading throughout Japan and has caused serious damage to populations of ayu Plecoglossus altivel in many farms and rivers. The rapid method of detecting for F. psuchrophilum is requested, however, traditional methods are laborious because of complicated assay procedures. In this study, a rapid method of detecting F. psychrophilum was developed using a modified method of flow cytometry (FCM) analysis and immunomagnetic separation (IMS). Magnetic iron, in small particles, was prepared by the reaction of a mixture of ferric and ferrous ions under alkaline conditions. The particles were coated with antiserum against F. psychrophilum by dextran. Polyclonal antibodies (anti-F. psychrophilum) conjugated with fluorescein isothiocyanate (FITC) were reacted with F. psychrophilum, and then prepared immunomagnetic were applied using IMS, followed by FCM determination. A good correlation was observed between the cell numbers determined by the FCM method and the traditional method in the range of 10(2)-10(8) cells ml(-1). The FCM analysis could count cells within 1min, and the total analysis time, including sample preparation, was less than 2 h.

Cell Separation↗