Search PubMed⌕ Search

PubMed · 16871003

Response surface optimization for joint contact model evaluation.

Abstract

When optimization is used to evaluate a joint contact model's ability to reproduce experimental measurements, the high computational cost of repeated contact analysis can be a limiting factor. This paper presents a computationally-efficient response surface optimization methodology to address this limitation. Quadratic response surfaces were fit to contact quantities (contact force, maximum pressure, average pressure, and contact area) predicted by a discrete element contact model of the tibiofemoral joint for various combinations of material modulus and relative bone pose (i.e., position and orientation). The response surfaces were then used as surrogates for costly contact analyses in optimizations that minimized differences between measured and predicted contact quantities. The methodology was evaluated theoretically using six sets of synthetic (i.e., computer-generated) contact data, and practically using one set of experimental contact data. For the synthetic cases, the response surface optimizations recovered all contact quantities to within 3.4% error. For the experimental case, they matched all contact quantities to within 6.3% error except for maximum contact pressure, which was in error by up to 50%. Response surface optimization provides rapid evaluation of joint contact models within a limited range of relative bone poses and can help identify potential weaknesses in contact model formulation and/or experimental data quality.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Yi-Chung Lin, Jack Farr, Kevin Carter, Benjamin J Fregly. 2006. Response surface optimization for joint contact model evaluation.. https://doi.org/10.1123/jab.22.2.120

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Experimental validation of noninvasive referencing in navigated procedures on long bones.

Navigation procedures in orthopedic surgery require fixation of reference markers to the anatomic region of interest. Inadequate fixation might lead to micromotion or loosening of the reference marker, consequently causing registration failures or errors in navigation. Osseous rigid fixation is usually achieved by minimally invasive Schanz screws or pins. The goal of this study was to evaluate a non invasive external fixation device, a headband so far used in cranial navigation, as an alternative invasive fixation technique to reference markers in the femur. A common navigation system with an adapted trauma software application was used to track the positions of the soft tissue-attached headband relative to an invasive reference marker on the femur during manipulations of the thigh. Relative translative and rotational movements of the headband were measured during defined movements of the hip and knee and manipulations of the headband itself. The results revealed high translative and rotational movements, up to 6 mm and 3 degrees , respectively, due to minor manipulations of the affected lower extremity. Noninvasive soft tissue fixation with a headband does not allow rigid fixation for accurate navigated registration or operative procedures at the femur. Necessary intraoperative movements or manipulations would cause substantial registration failures. Invasive fixation techniques with screws or pins are still the method of choice.

Bone Screws↗

Safety of computer-assisted surgery for cannulated hip screws.

Computer-assisted orthopaedic surgery has developed considerably during the past few years. Several manufacturers produce hardware and software for use in trauma surgery. Validation of these systems before clinical application is mandatory to be sure they work accurately and safely. The accuracy of surgical performance is highly correlated with the cut-out percentages of hip screws. In a standardized operative setting, three cannulated hip screws were inserted in each of 20 sawbones. The screws were positioned either by fluoroscopic navigation technique or by conventional operative technique depending on randomization. Our primary aim was to assess whether computer-navigated screw fixation is equally safe compared with conventional screw fixation using fluoroscopy. To determine safety, we investigated number of drilling attempts, screw position, and radiation time. Secondary to these safety parameters, we also compared the operating time between the two procedures to assess the efficiency of computer navigation. Statistical analysis showed no differences regarding accuracy of screw position. Computer-assisted surgery resulted in fewer drilling attempts and less radiation time, with a similar operation time. We believe the currently used navigation system is safe and accurate.

Bone Screws↗

A combined fracture of the greater and lesser tuberosity with head shaft continuity in the proximal humerus.

We treated a combined fracture of the greater and lesser tuberosity with head shaft continuity in the proximal humerus. This case is impossible to classify in three of the classifications, the Neer classification, AO Müller classification, or Jakob classification. However, this case has been described as fracture types in two different categories in the Codman classification. Based on our experience with this case, we concluded that both the plain radiographs and the CT scans were necessary to make a correct diagnosis and classify the fractures of the proximal humerus.

Bone Screws↗