Search PubMed⌕ Search

PubMed · 16831941

Bone strength: current concepts.

Abstract

Bones serve several mechanical functions, including acoustic amplification in the middle ear, shielding vital organs from trauma, and serving as levers for muscles to contract against. Bone is a multiphase material made up of a tough collagenous matrix intermingled with rigid mineral crystals. The mineral gives bone its stiffness. Without sufficient mineralization, bones will plastically deform under load. Collagen provides toughness to bone making it less brittle so that it better resists fracture. Bone adapts to mechanical stresses largely by changing its size and shape, which are major determinants of its resistance to fracture. Tissue is added in regions of high mechanical stress providing an efficient means for improving bone strength. Experiments have shown that small additions of bone mineral density (BMD) (5-8%) caused by mechanical loading can improve bone strength by over 60% and extend bone fatigue life by 100-fold. Consequently, it is clear that bone tissue possesses a mechanosensing apparatus that directs osteogenesis to where it is most needed for improving bone strength. The biological processes involved in bone mechanotransduction are poorly understood and further investigation of the molecular mechanisms involved might uncover drug targets for osteoporosis. Several pathways are emerging from current research, including membrane ion channels, ATP signaling, second messengers, such as prostaglandins and nitric oxide, insulin-like growth factors, and Wnt signaling.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Charles H Turner. 2006. Bone strength: current concepts.. https://doi.org/10.1196/annals.1346.039

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The effect of excessive tibial torsion on the capacity of muscles to extend the hip and knee during single-limb stance.

Excessive tibial torsion, a rotational deformity about the long axis of the tibia, is common in patients with cerebral palsy who walk with a crouch gait. Previous research suggests that this deformity may contribute to crouch gait by reducing the capacity of soleus to extend the knee; however, the effects of excess external torsion on the capacity of other muscles to extend the stance limb during walking are unknown. A computer model of the musculoskeletal system was developed to simulate a range of tibial torsion deformities. A dynamic analysis was then performed to determine the effect of these deformities on the capacity of lower limb muscles to extend the hip and knee at body positions corresponding to the single-limb stance phase of a normal gait cycle. Analysis of the model confirmed that excessive external torsion reduces the extension capacity of soleus. In addition, our analysis revealed that several important muscles crossing the hip and knee are also adversely affected by excessive tibial torsion. With a tibial torsion deformity of 30 degrees , the capacities of soleus, posterior gluteus medius, and gluteus maximus to extend both the hip and knee were all reduced by over 10%. Since a tibial torsion deformity reduces the capacity of muscles to extend the hip and knee, it may be a significant contributor to crouch gait, especially when greater than 30 degrees from normal, and thus should be considered by clinicians when making treatment decisions.

Biomechanical Phenomena↗

Predicting the subject-specific primary stability of cementless implants during pre-operative planning: preliminary validation of subject-specific finite-element models.

Pre-operative planning help the surgeon in taking the proper clinical decision. The ultimate goal of this work is to develop numerical models that allow the surgeon to estimate the primary stability during the pre-operative planning session. The present study was aimed to validate finite-element (FE) models accounting for patient and prosthetic size and position as planned by the surgeon. For this purpose, the FE model of a cadaveric femur was generated starting from the CT scan and the anatomical position of a cementless stem derived by a skilled surgeon using a pre-operative CT-based planning simulation software. In-vitro experimental measurements were used as benchmark problem to validate the bone-implant relative micromotions predicted by the patient-specific FE model. A maximum torque in internal rotation of 11.4 Nm was applied to the proximal part of the hip stem. The error on the maximum predicted micromotion was 12% of the peak micromotion measured experimentally. The average error over the entire range of applied torques was only 7% of peak measurement. Hence, the present study confirms that it is possible to accurately predict the level of primary stability achieved for cementless stems using numerical models that account for patient specificity and surgical variability.

Biomechanical Phenomena↗

Experimental validation of intact and implanted distal femur finite element models.

Four finite element (FE) models of intact and distal femur of knee replacements were validated relative to measured bone strains. FE models of linear tetrahedrons were used. Femoral replacements with cemented stemless, cemented and noncemented femoral stems of the PFC Sigma Modular Knee System were analyzed. Bone strains were recorded at ten locations on the cortex. The magnitude of the FE bone strains corresponded to the mean measured strains, with an overall agreement of 10%. Linear regression between the FE and mean experimental strains produced slopes between 0.94 and 1.06 and R(2) values between 0.92 and 0.99. RSME values were less than 12%. The FE models were able to adequately replicate the mechanical behavior of distal femur reconstructions.

Biomechanical Phenomena↗