Protein separations.

Abstract

This chapter describes the use of two types of commercialized microfluidic chips for protein separation, suitable for personal scale and high-throughput use. Compared with conventional approaches, such as sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) and capillary electrophoresis (CE), these devices offer the advantages of faster separation times, better data reproducibility, greater ease of use, labor savings in quantitative analysis, and ease in data archiving and data sharing owing to the digital data format. With some simple precautions taken to keep bubbles and particulates out of the microchannels, Lab-on-a-Chip devices have been adopted by many researchers in protein processing, protein engineering, and proteomics research laboratories to increase their productivity.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Andrea W Chow. 2006. Protein separations.. https://doi.org/10.1385/1-59745-076-6%3A145

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Ultrasonic standing wave manipulation technology integrated into a dielectrophoretic chip.

Several cell-based biological applications in microfluidic systems require simultaneous high-throughput and individual handling of cells or other bioparticles. Available chip-based tools for contactless manipulation are designed for either high-precision handling of individual particles, or high-throughput handling of ensembles of particles. In order to simultaneously perform both, we have combined two manipulation technologies based on ultrasonic standing waves (USWs) and dielectrophoresis (DEP) in a microfluidic chip. The principle is based on the competition between long-range ultrasonic forces, short-range dielectrophoretic forces and viscous drag forces from the fluid flow. The ultrasound is coupled into the microchannel resonator by an external transducer with a refractive element placed on top of the chip, thereby allowing transmission light microscopy to continuously monitor the biological process. The DEP manipulation is generated by an electric field between co-planar microelectrodes placed on the bottom surface of the fluid channel. We demonstrate flexible and gentle elementary manipulation functions by the use of USWs and linear or curved DEP deflector elements that can be used in high-throughput biotechnology applications of individual cells.

Electrophoresis, Microchip↗

Rapid on-column analysis of glucosamine and its mutarotation by microchip capillary electrophoresis.

A novel electrophoretic microchip method for analyzing alpha- and beta-d-glucosamine and their interconversion in solution is presented. d-Glucosamine is labeled with fluorescamine and analyzed by capillary electrophoresis in under 2 min revealing its pH-dependent mutarotation between the alpha- and beta-anomers. The forward interconversion rates for the labeled sugars, based on an iterative analysis of the plateau heights between the peaks, are 0.72+/-0.09, 1.3+/-0.1, and 2.2+/-0.3 x 10(-3)s(-1) at pH 8.99, 9.51 and 10.01, respectively. In a separate experiment, the mutarotation of the unlabeled alpha-d-anomer was followed; the relative intensities of the alpha- and beta-peaks as a function of reaction time at pH 9.51 give a forward rate constant of 0.6+/-0.1 x 10(-3)s(-1). These results demonstrate that fast microchip separations, previously exploited for amine, amino acid, and nucleobase analysis, can also be used to analyze amino sugars and their mutarotation.

Electrophoresis, Microchip↗

Dielectrophoresis field flow fractionation of single-walled carbon nanotubes.

We report a study on Dielectrophoresis Field Flow Fractionation of Single-Wall Carbon Nanotubes (SWNTs). SWNTs, individually suspended in 1% SDBS solution, were separated by type when they passed a dielectrophoresis field flow fractionation device where 1 MHz AC voltage was supplied and the field strength was well below 1 V per mum. Furthermore, we uniquely observed enrichment of semiconductive SWNTs based on their band gap. In addition to Raman spectrum, UV-vis absorption and NIR fluorescence spectra were used for solution samples for characterization.

Electrophoresis, Microchip↗