Search PubMed⌕ Search

PubMed · 16781166

Testing anatomically specified hypotheses in functional imaging using cytoarchitectonic maps.

Abstract

The statistical inference on functional imaging data is severely complicated by the embedded multiple testing problem. Defining a region of interest (ROI) where the activation is hypothesized a priori helps to circumvent this problem, since in this case the inference is restricted to fewer simultaneous tests, rendering it more sensitive. Cytoarchitectonic maps obtained from postmortem brains provide objective, a priori ROIs that can be used to test anatomically specified hypotheses about the localization of functional activations. We here analyzed three methods for the definition of ROIs based on probabilistic cytoarchitectonic maps. (1) ROIs defined by the volume assigned to a cytoarchitectonic area in the summary map of all areas (maximum probability map, MPM), (2) ROIs based on thresholding the individual probabilistic maps and (3) spherical ROIs build around the cytoarchitectonic center of gravity. The quality with which the thus defined ROIs represented the respective cytoarchitectonic areas as well as their sensitivity for detecting functional activations was subsequently statistically evaluated. Our data showed that the MPM method yields ROIs, which reflect most adequately the underlying anatomical hypotheses. These maps also show a high degree of sensitivity in the statistical analysis. We thus propose the use of MPMs for the definition of ROIs. In combination with thresholding based on the Gaussian random field theory, these ROIs can then be applied to test anatomically specified hypotheses in functional neuroimaging studies.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Simon B Eickhoff, Stefan Heim, Karl Zilles, Katrin Amunts. 2006-06-14. Testing anatomically specified hypotheses in functional imaging using cytoarchitectonic maps.. https://doi.org/10.1016/j.neuroimage.2006.04.204

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗