Search PubMed⌕ Search

PubMed · 16750060

Pressure relieving support surfaces: a randomised evaluation.

Abstract

OBJECTIVES: To determine differences between alternating pressure overlays and alternating pressure replacement mattresses with respect to the development of new pressure ulcers, healing of existing pressure ulcers, patient acceptability and cost-effectiveness of the different pressure-relieving surfaces. Also to investigate the specific additional impact of pressure ulcers on patients' well-being. DESIGN: A multicentre, randomised, controlled, open, fixed sample, parallel-group trial with equal randomisation was undertaken. The trial used remote, concealed allocation and intention-to-treat (ITT) analysis. The main trial design was supplemented with a qualitative study involving a purposive sample of 20-30 patients who developed pressure ulcers, to assess the impact of the pressure ulcers on their well-being. In addition, a focus group interview was carried out with clinical research nurses, who participated in the PRESSURE (Pressure RElieving Support SUrfaces: a Randomised Evaluation) Trial, to explore the experiences of their role and observations of pressure area care. SETTING: The study took place in 11 hospital-based research centres within six NHS trusts in England. PARTICIPANTS: Acute and elective patients aged 55 years or older and admitted to vascular, orthopaedic, medical or care of the elderly wards in the previous 24 hours were investigated. INTERVENTIONS: Patients were randomised to either an alternating pressure overlay or an alternating pressure mattress replacement, with mattress specifications clearly defined to enable the inclusion of centres using products from different manufacturers, and to exclude hybrid mattress systems (which either combine foam or constant low pressure with alternating pressure in one mattress, or can be used as either an overlay or a replacement mattress). MAIN OUTCOME MEASURES: Development of a new pressure ulcer (grade < or =2, i.e. partial-thickness wound involving epidermis/dermis only) on any skin site. Also healing of existing pressures ulcers, patient acceptability and cost-effectiveness. RESULTS: In total, 6155 patients were assessed for eligibility to the trial and 1972 were randomised: 990 to the alternating pressure overlay (989 after one postrandomisation exclusion) and 982 to the alternating pressure mattress replacement. ITT analysis found no statistically significant difference in the proportions of patients developing a new pressure ulcer of grade 2 or above [10.7% overlay patients, 10.3% mattress replacement patients, a difference of 0.4%, 95% confidence interval (CI) -2.3 to 3.1%, p = 0.75]. When logistic regression analysis was used to adjust for minimisation factors and prespecified baseline covariates, there was no difference between the mattresses with respect to the odds of ulceration (odds ratio 0.94, 95% CI 0.68 to 1.29). There was no evidence of a difference between the mattress groups with respect to time to healing (p = 0.86). The Kaplan-Meier estimate of the median time to healing was 20 days for each intervention. More patients allocated overlays requested mattress changes due to dissatisfaction (23.3%) than mattress replacement patients (18.9%, p = 0.02) and more than one-third of patients reporting difficulties associated with movement in bed and getting into or out of bed. There is a higher probability (64%) that alternating mattress replacements are cost-saving; they were associated with lower overall costs (74.50 pounds sterling per patient on average, mainly due to reduced length of stay) and greater benefits (a delay in time to ulceration of 10.64 days on average). Patients' accounts highlighted that the development of a pressure ulcer could be pivotal in the trajectory from illness to recovery, by preventing full recovery or causing varied impacts on their quality of life. CONCLUSIONS: There is no difference between alternating pressure mattress replacements and overlays in terms of the proportion of patients developing new pressure ulcers; however, alternating pressure mattress replacements are more likely to be cost-saving. The results suggest that when renewing alternating pressure surfaces or ordering equipment within a rental contract, mattress replacements should be specified; however, overlays are acceptable if no replacement mattress is available. Similarly, patient preferences can be supported, without any great increase in risk, if individual patients request an overlay rather than a replacement mattress. Further research could include a randomised controlled trial comparing alternating pressure mattress replacements and high-specification foam mattresses in patients at moderate to high risk; an accurate costing study to understand better how much pressure ulcers cost health and social services in the UK; and trials in higher risk groups of patients. Also future trials should measure time to ulceration as the primary end-point, since this is more informative economically and possibly also from a patient and clinical perspective.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Nixon, E A Nelson, G Cranny, C P Iglesias, K Hawkins, N A Cullum, A Phillips, K Spilsbury, D J Torgerson, S Mason, PRESSURE Trial Group. 2006. Pressure relieving support surfaces: a randomised evaluation.. https://doi.org/10.3310/hta10220

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Natural cellulose fibers from switchgrass with tensile properties similar to cotton and linen.

We report the production and characteristics of natural cellulose fibers obtained from the leaves and stems of switchgrass. In this paper, the composition, structure and properties of fibers obtained from the leaves and stem of switchgrass have been studied in comparison to the common natural cellulose fibers, such as cotton, linen and kenaf. The leaves and stems of switchgrass have tensile properties intriguingly similar to that of linen and cotton, respectively. Fibers were obtained from the leaves and stems of switchgrass using a simple alkaline extraction and the structure and properties of the fibers were studied. Fibers obtained from switchgrass leaves have crystallinity of 51%, breaking tenacity of 5.5 g per denier (715 MPa) and breaking elongation of 2.2% whereas the corresponding values for fibers obtained from switchgrass stems are 46%, 2.7 g per denier and 6.8%, respectively. Switchgrass is a relatively easy to grow and high yield biomass crop that can be source to partially substitute the natural and synthetic fibers currently in use. We hope that this research will stimulate interests in using switchgrass as a novel fiber crop in addition to being promoted as a potential source for biofuels.

Bedding and Linens↗

Efficacy of forced-air warming systems with full body blankets.

PURPOSE: Postoperative hypothermia after cardiac surgery is still a common problem often treated with forced-air warming. This study was conducted to determine the heat transfer efficacy of 11 forced-air warming systems with full body blankets on a validated copper manikin. METHODS: The following systems were tested: 1) Bair Hugger 505; 2) Bair Hugger 750; 3) Life-Air 1000 S; 4) Snuggle Warm; 5) Thermacare; 6) Thermacare with reusable Optisan blanket; 7) WarmAir; 8) Warm-Gard; 9) Warm-Gard and reusable blanket; 10) WarmTouch; and 11) WarmTouch and reusable blanket. Heat transfer of forced-air warmers can be described as follows: Q = h x DeltaT x A. Where Q = heat flux (W), h = heat exchange coefficient (W x m-2 x degrees C-1), DeltaT = temperature gradient between blanket and manikin surface (degrees C), A = covered area (m2). Heat flux per unit area and surface temperature were measured with 16 heat flux transducers. Blanket temperature was measured using 16 thermocouples. The temperature gradient between blanket and surface (DeltaT) was varied and h was determined by linear regression analysis. Mean DeltaT was determined for surface temperatures between 32 degrees C and 38 degrees C. The covered area was estimated to be 1.21 m2. RESULTS: For the 11 devices, heat transfers of 30.7 W to 77.3 W were observed for surface temperatures of 32 degrees C, and between -8.8 W to 29.6 W for surface temperatures of 38 degrees C. CONCLUSION: There are clinically relevant differences between the tested forced-air warming systems with full body blankets. Several systems were unable to transfer heat to the manikin at a surface temperature of 38 degrees C.

Bedding and Linens↗