A microfluidic multi-injector for gradient generation.

Abstract

This paper describes a microfluidic multi-injector (MMI) that can generate temporal and spatial concentration gradients of soluble molecules. Compared to conventional glass micropipette-based methods that generate a single gradient, the MMI exploits microfluidic integration and actuation of multiple pulsatile injectors to generate arbitrary overlapping gradients that have not previously been possible. The MMI device is fabricated in poly(dimethylsiloxane) (PDMS) using multi-layer soft lithography and consists of fluidic channels and control channels with pneumatically actuated on-chip barrier valves. Repetitive actuation of on-chip valves control pulsatile release of solution that establishes microscopic chemical gradients around the orifice. The volume of solution released per actuation cycle ranged from 30 picolitres to several hundred picolitres and increased linearly with the duration of valve opening. The shape of the measured gradient profile agreed closely with the simulated diffusion profile from a point source. Steady state gradient profiles could be attained within 10 minutes, or less with an optimized pulse sequence. Overlapping gradients from 2 injectors were generated and characterized to highlight the advantages of MMI over conventional micropipette assays. The MMI platform should be useful for a wide range of basic and applied studies on chemotaxis and axon guidance.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Bong Geun Chung, Francis Lin, Noo Li Jeon. 2006-04-06. A microfluidic multi-injector for gradient generation.. https://doi.org/10.1039/b512667c

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Glass-fiber reinforced poly(acrylate)-based sorptive materials for the enrichment of organic micropollutants from aqueous samples.

A novel and simple approach to sorptive materials for the extraction of organic compounds from environmental samples is presented. It entails the use of glass fiber fabric strips coated with a customized poly(acrylate) (PA) formulation as extraction medium. Analytes were enriched by means of shaking of the PA strip in the sample and then subsequently thermally desorbed and analyzed by GC-MS. The performance of the sorptive materials was evaluated by the enrichment of compounds with different polarities (phenols, hexachlorobenzene and hexachlorocyclohexanes) from water samples. Parameters that affect the extraction process such as pH, ionic strength of the solvent, mixing mechanism, extraction time and desorption conditions were investigated. The extraction abilities of the PA extraction medium were compared with that of commercially available poly(dimethylsiloxane) (PDMS) Twisters. The results revealed that the new material shows higher affinity for phenolic compounds presumably due to the presence of polar groups. The partition coefficients for the PA strips estimated in this work were up to 15 times higher than for the PDMS Twister, resulting in higher recoveries and lower detection limits. The method was applied for the quantification of the aforementioned compounds in contaminated surface water samples from Bitterfeld (Germany). Using both PA strips and PDMS Twisters, good agreement of the extraction data was achieved.

Dimethylpolysiloxanes↗

Microfluidic serial dilution circuit.

In vitro evolution of RNA molecules requires a method for executing many consecutive serial dilutions. To solve this problem, a microfluidic circuit has been fabricated in a three-layer glass-PDMS-glass device. The 400-nL serial dilution circuit contains five integrated membrane valves: three two-way valves arranged in a loop to drive cyclic mixing of the diluent and carryover, and two bus valves to control fluidic access to the circuit through input and output channels. By varying the valve placement in the circuit, carryover fractions from 0.04 to 0.2 were obtained. Each dilution process, which is composed of a diluent flush cycle followed by a mixing cycle, is carried out with no pipeting, and a sample volume of 400 nL is sufficient for conducting an arbitrary number of serial dilutions. Mixing is precisely controlled by changing the cyclic pumping rate, with a minimum mixing time of 22 s. This microfluidic circuit is generally applicable for integrating automated serial dilution and sample preparation in almost any microfluidic architecture.

Dimethylpolysiloxanes↗