Search PubMed⌕ Search

PubMed · 16705629

Parallel imaging.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jo V Hajnal, David J Larkman. 2006. Parallel imaging.. https://doi.org/10.1002/nbm.1054

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Medical diagnostic applications and sources.

The ways in which ultrasound is used in medical diagnosis are reviewed, with particular emphasis on the ultrasound source (probe) and implications for acoustic exposure. A brief discussion of the choice of optimum frequency for various target depths is followed by a description of the general features of diagnostic ultrasound probes, including endo-probes. The different modes of diagnostic scanning are then discussed in turn: A-mode, M-mode, B-mode, three-dimensional (3D) and 4D scanning, continuous wave (CW) Doppler, pulse-wave spectral Doppler and Doppler imaging. Under the general heading of B-mode imaging, there are individual descriptions of the principles of chirps and binary codes, B-flow, tissue harmonic imaging and ultrasound contrast agent-specific techniques. Techniques for improving image quality within the constraints of real-time operation are discussed, including write zoom, parallel beam forming, spatial compounding and multiple zone transmission focusing, along with methods for reducing slice thickness. At the end of each section there is a summarising comment on the basic features of the acoustic output and its consequences for patient safety.

Image Enhancement↗

Differential ultrasonic imaging for the characterization of lesions induced by high intensity focused ultrasound.

High intensity focused ultrasound (HIFU) is an effective technique for noninvasive local creating coagulative necrotic lesions in deep target volumes without damage to the overlaying or surrounding tissues. It is very important to detect and evaluate lesions generated by HIFU during treatment procedures. This study describes the development of several differential ultrasonic imaging techniques to characterize lesions based on estimation of relative changes in tissue properties derived from backscattered RF data. A single, spherical HIFU transducer was used to produce lesions in soft tissues. The RF signals were recorded as outputs from a modified diagnostic ultrasound system. After some preprocessing, the integrated backscatter values, which can be used as an indicator of the microstructure and backscattering property of tissues, were calculated before and after HIFU treatment. The differential integrated backscatter values were subsequently used to form images revealing the lesion areas. The differential attenuation imaging with the same RF data was also performed, which has been proposed by a few researchers. The results of the differential integrated backscatter imaging were compared with that of the differential attenuation imaging and the former method offers some advantages over the latter method. The two methods above are both based on spectrum analysis and would spend much computational time. Therefore, some simple digital differential imaging methods, including absolute difference (AD), sum absolute differences (SAD), and sum squared differences (SSD) algorithms, were also proposed to detect HIFU-induced lesions. However, these methods cannot provide the information of the degree of tissue damage. Experiments in vitro bovine muscle and liver validated the method of differential integrated backscatter imaging for the characterization of HIFU-induced lesions. And the AD, SAD, and SSD algorithms can be implemented in real-time during HIFU therapy to visualize the lesions.

Image Enhancement↗

High-sensitivity vibrational imaging with frequency modulation coherent anti-Stokes Raman scattering (FM CARS) microscopy.

We demonstrate a new approach to coherent anti-Stokes Raman scattering (CARS) microscopy that significantly increases the detection sensitivity. CARS signals are generated by collinearly overlapped, tightly focused, and raster scanned pump and Stokes laser beams, whose difference frequency is rapidly modulated. The resulting amplitude modulation of the CARS signal is detected through a lock-in amplifier. This scheme efficiently suppresses the nonresonant background and allows for the detection of far fewer vibrational oscillators than possible through existing CARS microscopy methods.

Image Enhancement↗