Search PubMed⌕ Search

PubMed · 16686299

Bicarbonate solutions: update.

Abstract

The use of lactate-based peritoneal dialysis solutions (PDFs) requires hepatic metabolism to convert lactate to bicarbonate. Pure bicarbonate solutions are particularly useful in the setting of hepatic dysfunction and whenever a high risk of lactate accumulation in the blood exists. This article reviews the recent literature related to laboratory findings and clinical experiences with bicarbonate-containing PDFs. The data suggest that bicarbonate-based solutions are safe and well tolerated and that, among patients with severe metabolic acidosis, they provide better correction of that acidosis than do lactate-containing PDFs. In addition, use of bicarbonate solution seems to be associated with improved nutrition, better growth rate in children with end-stage renal disease, better preservation of residual renal function, and, possibly, higher peritoneal ultrafiltration and a lower peritonitis rate. More experience with these solutions and more prospective controlled studies should be encouraged to further characterize the potential benefits of bicarbonate solutions.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jose A Diaz-Buxo. 2005. Bicarbonate solutions: update.. https://pubmed.ncbi.nlm.nih.gov/16686299/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Gadolinium is detectable within the tissue of patients with nephrogenic systemic fibrosis.

BACKGROUND: Nephrogenic systemic fibrosis (NSF) is a disease of unknown etiology that affects a subset of patients with renal insufficiency. Recent publications suggested an association between exposure to gadolinium-containing contrast agents and subsequent development of NSF. We sought to detect gadolinium within the skin and soft tissue of patients with NSF who were exposed to gadolinium-based contrast. METHODS: Paraffin-embedded skin and soft tissue from NSF patients exposed to gadolinium, and from negative controls, was provided by the NSF Registry (New Haven, Conn). The tissue was searched for metals using a field emission scanning electron microscope that was equipped with energy dispersive spectroscopy. The presence of gadolinium and other metals was verified through identification of unique and requisite X-ray emission spectra. RESULTS: Gadolinium was detected in 4 of 13 tissue specimens from 7 patients with documented NSF who were exposed to gadolinium-based radiographic contrast. No gadolinium was detected in a paraffin-embedded specimen from a negative control. Based upon the known exposure history of patients with detectable gadolinium, a tissue residence time of 4 to 11 months was observed. LIMITATIONS: As this was a pilot investigation, only a single control specimen and a single histological section from each block of tissue were utilized. CONCLUSION: In this pilot investigation, gadolinium was detected in the tissue of a number of patients with NSF. Although neither dispositive of a pathophysiologic mechanism, nor proof of causation, the detection of gadolinium within tissue of NSF patients is supportive of an epidemiologic association between exposure to gadolinium-containing contrast material and development of disease.

Acidosis↗

Relationship between intertwin delivery interval and metabolic acidosis in the second twin.

This study sought to assess the relationship between intertwin delivery interval (ITDI) and metabolic acidosis in the second twin at birth using a retrospective twin delivery cohort from a tertiary-level teaching hospital. Twin births were identified from an obstetrical database during a 10-year period from 1994 to 2004. Mean arterial cord pH and base deficit among different ITDIs were compared by analysis of variance. Logistic regression models were used to estimate effects of ITDI on metabolic acidosis. The incidence of metabolic acidosis in the second twin was defined as pH < 7.0, and base deficit was defined as >or= 12 mmol/L at birth. After excluding those pregnancies with both twins delivered by cesarean section, birthweight less than 750 g of either twin, antepartum death of either twin, or second twins with missing cord arterial pH, we had 310 twin pairs left for final analysis. Mean pH was significantly lower and base deficit significantly higher for second twin after ITDI exceeded 60 minutes. The incidence of metabolic acidosis increased with increasing ITDI (chi2 test for linear trend, P = 0.02) and the risk of metabolic acidosis (odds ratio, 22.6; 95% confidence interval, 2.5 to 494.1) was increased in the second twins with ITDI longer than 60 minutes compared with those with ITDI less than 15 minutes. The incidence of metabolic acidosis increases with increasing ITDI and there is a statistically significant increased risk of neonatal acidosis after longer than 60 minutes compared with less than 15 minutes of ITDI.

Acidosis↗

Spatiotemporal pH dynamics following insertion of neural microelectrode arrays.

Insertion trauma is a critical issue when assessing intracortical electrophysiological and neurochemical recordings. Previous reports document a wide variety of insertion techniques with speeds ranging from 10 microm/s to 10 m/s. We hypothesize that insertion speed has an effect on tissue trauma induced by implantation of a neural probe. In order to monitor the neural interface during and after probe insertion, we have developed a silicon-substrate array with hydrous iridium oxide microelectrodes for potentiometric recording of extracellular pH (pH(e)), a measure of brain homeostasis. Microelectrode sites were sensitive to pH in the super-Nernstian range (-85.9 mV/pH unit) and selective over other analytes including ascorbic acid, Na(+), K(+), Ca(2+), and Mg(2+). Following insertion, arrays recorded either triphasic or biphasic pH(e) responses, with a greater degree of prolonged acidosis for insertions at 50 microm/s than at 0.5 mm/s or 1.0 mm/s (p<0.05). Spatiotemporal analysis of the recordings also revealed micro-scale variability in the pH(e) response along the array, even when using the same insertion technique. Implants with more intense acidosis were often associated histologically with blood along the probe tract. The potentiometric microsensor array has implications not only as a useful tool to measure extracellular pH, but also as a feedback tool for delivery of pharmacological agents to treat surgical brain trauma.

Acidosis↗