Search PubMed⌕ Search

PubMed · 16685577

Interviewer variability - quality aspects in a case-control study.

Abstract

Quality assurance and quality control are important for the reliability of case-control studies. Here we describe the procedures used in a previously published study, with emphasis on interviewer variability. To evaluate risk factors for acute pancreatitis, information including previous diagnoses and medication was collected from medical records and by telephone interviews from 462 cases and 1781 controls. Quality assurance procedures included education and training of interviewers and data validity checks. Quality control included a classification test, annual test interviews, expert case validation, and database validation. We found pronounced variations between interviewers. The maximal number of interviews per day varied from 3 to 9. The adjusted average (95% CI) number of diagnoses captured per interview of cases was 4.1 (3.8-4.3) and of controls 3.5 (3.4-3.7) (excluding one deviating interviewer). For drugs, the average (95% CI) number per interview was 3.9 (3.7-4.1) for cases and 3.3 (3.2-3.4) for controls (excluding one deviating interviewer). One of the fourteen interviewers deviated significantly from the others, and more so for controls than for cases. This interviewer's data ;were excluded. Nonetheless, data concerning controls more frequently needed correction and supplementation than for cases. Erroneous coding of diagnoses and medication was also more frequent among controls. Thus, a system for quality control of coding practices is crucial. Variability in interviewers' ability to ascertain information is a possible source of bias in interview-based case-control studies when "blinding" cannot be achieved.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Kerstin J Blomgren, Anders Sundström, Gunnar Steineck, Bengt-Erik Wiholm. 2006. Interviewer variability - quality aspects in a case-control study.. https://doi.org/10.1007/s10654-006-0017-7

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The effect of acute pain crisis on exhaled nitric oxide levels in children with sickle cell disease.

Exhaled nitric oxide (FE(NO)) has been shown to be decreased in children with sickle cell disease. We sought to evaluate the effect of sickle cell vaso-occlusive crisis (VOC) on FE(NO) levels. We measured FE(NO) levels in 42 children with sickle cell disease, 29 in their baseline health and 13 during an acute VOC. There was no difference in FE(NO) levels between children at baseline (15.12 +/- 9.32 ppb) and those during an acute VOC (15.68 +/- 7.26 ppb; P = 0.794). FE(NO) is not a useful marker of acute VOC in children with sickle cell disease.

Acute Disease↗

[Megadolichobasilar anomaly causing acute deafness with vertigo].

Megadolichobasilar anomaly, a dilatant arteriopathy of the basilar artery attributable to chronic arterial hypertension, can cause cranial nerve compression syndromes of the cerebellopontine angle or infarcts of the vertebrobasilar circulation. In this paper, we report on a patient with known megadolichobasilar anomaly and a partially thrombosed fusiform aneurysm of the basilar artery, who presented with acute-onset vertigo and subsequent deafness due to thromboembolic occlusion of the labyrinthine artery. Because of the vascular origin of the patient's symptoms, his vertigo disappeared over time while the deafness persisted.

Acute Disease↗

Retrieval of a leaflet escaped in a Tri-technologies bileaflet mechanical prosthetic valve.

The escape of the prosthetic heart valve disc is one of the causes of prosthetic dysfunction that requires emergency surgery. The removal of the embolized disc should be carried out because of the risk of a progressive extrusion on the aortic wall. Several imaging techniques can be used for the detection of the missing disc localization. In this report we describe a 32-year-old man who underwent mitral valve replacement with a Tri-technologies bileaflet valve three years ago, and was admitted in cardiogenic shock. Transesophageal echocardiography showed acute-onset massive mitral regurgitation. The patient underwent emergency replacement of the prosthetic valve. Only one of the two leaflets remained in the removed prosthetic valve. The missing leaflet could not be found within the cardiac cavity. The abdominal fluoroscopic study and plain radiography were unable to detect the escaped leaflet. The abdominal computed tomography scan and the ultrasound showed the escaped leaflet in the terminal portion of the aortic bifurcation. To retrieve the embolized disc laparotomy and aortotomy were performed three months later. The escaped leaflet shows a fracture of one of the pivot systems caused by structural failure. This kind of failure mode is usually the result of high stress concentration.

Acute Disease↗