Search PubMed⌕ Search

PubMed · 16639444

Static two-dimensional aperture coding for multimodal, multiplex spectroscopy.

Abstract

We propose a new class of aperture-coded spectrometer that is optimized for the spectral characterization of diffuse sources. The instrument achieves high throughput and high spectral resolution by replacing the slit of conventional dispersive spectrometers with a more complicated spatial filter. We develop a general mathematical framework for deriving the required aperture codes and discuss several appealing code families. Experimental results validate the performance of the instrument.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Michael E Gehm, Scott T McCain, Nikos P Pitsianis, David J Brady, Prasant Potuluri, Michael E Sullivan. 2006-05-01. Static two-dimensional aperture coding for multimodal, multiplex spectroscopy.. https://doi.org/10.1364/ao.45.002965

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Successful computer guided planned synthesis of (4R)-thiazolidine carboxylic acid and its 2-substituted analogues as urease inhibitors.

By using internal combinatorial library we were able to identify (4R)-thiazolidines carboxylic acid and its 2-substituted analogs as active inhibitors of urease. Molecular modeling and virtual screening were utilized to find out potential compounds. Computational techniques were employed at database of 90,000 ligands and selected the structure representing the low energy conformations, Grid and FlexX docking algorithms were used and the top binding ligands were synthesized and screened in wet-lab.

Computer-Aided Design↗

Surface plasmon resonance sensor based on polarization interferometry and angle modulation.

A surface plasmon resonance (SPR) sensing technique based on polarization interferometry and angle modulation is presented. Its sensitivity is not a direct function of variation of reflection intensity, nor of phase shift. Rather, it is a function of the complex reflection coefficient. A three times standard deviation detection limit of 5.1 x 10(-7) refractive index units in a 2 Hz bandwidth is obtained with our experimental setup. A theoretical analysis shows that this technique can provide a wide linear measurement range. Moreover, the sensitivity is insensitive to the thickness of gold films over approximately 5 nm. This SPR sensing technique is suitable for physical, chemical, and biological research.

Computer-Aided Design↗