Abstract

AIMS: To determine whether using a respiratory function monitor alters clinicians' choice of ventilator settings, tidal volumes or blood gases in the first 48 h of ventilation. METHODS: Clinicians were trained to use a respiratory function monitor to optimize neonatal ventilation. Thirty-five infants, weighing < 2 kg, treated with the Infant Star ventilator were randomized to have a respiratory function monitor display visible or concealed. All reasons for altering ventilator settings were noted. Data on ventilator parameters and clinical care were collected hourly. The primary outcome was the mean peak pressure used during the first 48 h. RESULTS: There were no statistically significant differences in peak pressures, tidal volumes or arterial carbon dioxide levels between the two groups. CONCLUSIONS: Using the Florian respiratory function monitor in the first 48 h of ventilation with the Infant Star ventilator did not alter the choice of ventilator settings, tidal or minute volumes or arterial blood gases. Possible explanations for this result include lack of power due to the small numbers recruited and bias due to the unblinded nature of the trial.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Jan Klimek, Colin John Morley, Rosalind Lau, Peter Graham Davis. 2006. Does measuring respiratory function improve neonatal ventilation?. https://doi.org/10.1111/j.1440-1754.2006.00813.x

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Does gas exchange response to prone position predict mortality in hypoxemic acute respiratory failure?

OBJECTIVE: To determine whether gas exchange response to a first prone position session can predict patient outcome in hypoxemic acute respiratory failure. METHODS: Data from a previous multicenter randomized controlled trial were retrospectively analyzed for relationship between PaO(2)/FIO(2) ratio and PaCO(2) changes during the first 8-h prone position session to day 28 mortality rate; 370 prone position sessions were analyzed. Arterial blood gas was measured in supine position before proning and in prone position at the end of the session. Gas exchange improvement was defined as increase in the PaO(2)/FIO(2) ratio of more than 20% (PaO(2)R) or decrease in PaCO(2) of more than 1 mmHg (PaCO(2)R). MAIN RESULTS: The 28-day mortality rate was 26.5% in PaO(2)R-PaCO(2)R, 31.7% in PaO(2)R-PaCO(2)NR, 38.9% in PaO(2)NR-PaCO(2)R, and 43% in PaO(2)NR-PaCO(2)NR (log-rank 14.02, p = 0.003). In a Cox proportional hazards model the gas exchange response was a significant predictor to patient outcome with a 82.5% increase in risk of death in the case of PaO(2)NR-PaCO(2)R or PaO(2)NR-PaCO(2)NR, relative to the gas exchange improvement response (odds ratio 1.825). However, after adjusting for the difference in oxygenation between day 2 and day 1 the gas exchange response does no longer reach significance. CONCLUSION: In patients with hypoxemic acute respiratory failure initial improvement in gas exchange in the first PP session was associated with a better outcome, but this association disappeared when the change in oxygenation from day 1 to day 2 was taken into account, suggesting that underlying illness was the most important predictor of mortality in this patient population.

Blood Gas Analysis↗

Effects of vertical positioning on gas exchange and lung volumes in acute respiratory distress syndrome.

OBJECTIVE: Supine position may contribute to the loss of aerated lung volume in patients with acute respiratory distress syndrome (ARDS). We hypothesized that verticalization increases lung volume and improves gas exchange by reducing the pressure surrounding lung bases. DESIGN AND SETTING: Prospective observational physiological study in a medical ICU. SUBJECTS AND INTERVENTION: In 16 patients with ARDS we measured arterial blood gases, pressure-volume curves of the respiratory system recorded from positive-end expiratory pressure (PEEP), and changes in lung volume in supine and vertical positions (trunk elevated at 45 degrees and legs down at 45 degrees ). MEASUREMENTS AND RESULTS: Vertical positioning increased PaO(2) significantly from 94+/-33 to 142+/-49 mmHg, with an increase higher than 40% in 11 responders. The volume at 20 cmH(2)O measured on the PV curve from PEEP increased using the vertical position only in responders (233+/-146 vs. -8+/-9 1ml in nonresponders); this change was correlated to oxygenation change (rho=0.55). End-expiratory lung volume variation from supine to vertical and 1 h later back to supine, measured in 12 patients showed a significant increase during the 1-h upright period in responders (n=7) but not in nonresponders (n=5; 215+/-220 vs. 10+/-22 ml), suggesting a time-dependent recruitment. CONCLUSIONS: Vertical positioning is a simple technique that may improve oxygenation and lung recruitment in ARDS patients.

Blood Gas Analysis↗

Prescribing oxygen therapy. An audit of oxygen prescribing practices on medical wards at North Shore Hospital, Auckland, New Zealand.

AIM: To assess the frequency and accuracy of inpatient oxygen prescription at North Shore Hospital, Auckland. METHOD: Between 14 April 2005 and 14 May 2005, 100 medical inpatients receiving oxygen therapy were randomly selected for chart review. For each patient, the clinical diagnosis, oxygen prescription (if present), and initial medical plan were analysed in conjunction with the oxygen flow rate and oxygen saturations (as documented in the observation chart). RESULTS: Only 8% of patients receiving oxygen had it prescribed in their medication chart. The majority (75%) of oxygen prescriptions were inadequate. CONCLUSION: Current rates of oxygen prescription on medical wards at North Shore Hospital, Auckland, are unsatisfactory. This poor oxygen prescription rate carries serious potential consequences.

Blood Gas Analysis↗