Search PubMed⌕ Search

PubMed · 16470901

Temperature-sensitive core-shell microgel particles with dense shell.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ingo Berndt, Jan Skov Pedersen, Walter Richtering. 2006-03-03. Temperature-sensitive core-shell microgel particles with dense shell.. https://doi.org/10.1002/anie.200503888

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Ion-selective channels in K562 cells: a patch-clamp analysis.

Four types of ion-selective channels were found by the patch-clamp technique in the human erythroleukemia K562 cells. I) in cell-attached configuration at potentials less negative than -40 mV an 8 ps channel was detected. The potential dependence of channel activity suggests that this is the TTX-sensitive Na+ channel. II) A cation-selective channel was observed with equal permeability for Na+ and K+ and a potential-independent single-channel conductance of 19 pS. The channel is activated by intracellular Ca2+ and inhibited by TEA, III) A predominantly anion-selective channel was identified with the selectivity sequence NO3- > J- > Cl- = Br- >> SO4(2-). The single-channel conductance shows outward rectification, and is in symmetrical NaCl solution 19 pS at -60 mV and 54pS at +50 mV. The open- and closed-time distributions suggest one open and at least four closed states. At submicromolar concentrations, the open state is blocked by H2DIDS leading to channel flicker between open and blocked channel; higher concentrations (apparent KI = 6.8 uM) lead to a longer-lasting blocked state. Both components of inhibition are reversible. IV) In addition, an 8 pS, Na(+)- and K(+)- selective channel could be induced by application of palytoxin. For channel activity, the presence of extracellular Na+ is essential. It is assumed that the Na+, K(+)-pump molecule is involved in the channel formation. Similarly, it is discussed whether the anion-selective channel represents a pore conformation of an electrically silent anion exchanger.

Acrylamides↗

Synthesis and temperature response analysis of magnetic-hydrogel nanocomposites.

Magnetically responsive hydrogel networks based on composites of magnetic nanoparticles and temperature responsive hydrogels were developed. These systems show great promise as active components of microscale and nanoscale devices and are expected to have a wide applicability in various biomedical applications. Specifically, nanocomposite hydrogel systems based on the temperature sensitive N-isopropylacrylamide hydrogels crosslinked with ethylene glycol dimethacrylate, tetraethylene glycol dimethacrylate, and poly(ethylene glycol) 400 dimethacrylate (PEG400DMA) were synthesized and characterized. The composite systems were synthesized by UV free-radical polymerization. Iron oxide magnetic nanoparticles were incorporated into the hydrogel systems by polymerizing mixtures of the nanoparticles and monomer solutions. The swelling response of these composite systems to different crosslinking molecular weights, temperature, and the effect of the presence of the magnetic nanoparticles were examined.

Acrylamides↗

Blood cell separation using amphiphilic copolymers containing N,N-dimethylacrylamide.

To develop leukocyte removal filters effective for whole blood, amphiphilic copolymers based on N,N-dimethylacrylamide were synthesized and evaluated as coating materials for poly(ethylene terephthalate) filters. The copolymers with methyl methacrylate or 2-hydroxypropyl methacrylate as a comonomer showed higher platelet permeation ratios (more than 90%) than that of the copolymer with n-butyl methacrylate, though the logarithmic reductions of leukocytes by these copolymers were less than four. An increase in the platelet permeation for whole blood tended to increase the leukocyte permeation. The permeation of both platelets and leukocytes increased with the amount of copolymer coated on the filters because of the change in the physical properties such as the average pore size, total surface area, and total pore volume of coated filters. These results confirm that both the chemical and physical properties of the filters play important roles to control the permeation behavior.

Acrylamides↗