Minimum detectable activity when background is counted longer than the sample.

Abstract

This note discusses the use of blank or background counting data that are measured for times that differ from times used for the sample counts. The correct formula for the minimum detectable activity, under this condition, is given as follows: MDA = [3 + 3.29 square root of Rbtg(1 + tg/tb)]/epsilon tg, where Rb denotes background count rate, tb and tg denote background and gross count times, and epsilon denotes counting efficiency. Counting backgrounds for a long time reduces decision levels, uncertainties, and minimum detectable activities. These benefits are fully available only when there is no other source of variability than random fluctuations in count rates.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D J Strom, P S Stansbury. 1992. Minimum detectable activity when background is counted longer than the sample.. https://doi.org/10.1097/00004032-199209000-00016

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Study of natural radionuclide concentrations in an area of elevated radiation background in the northern districts of Bangladesh.

The activity concentrations of naturally occurring radioactive materials in soil samples from an elevated radiation background area of three northern districts of Bangladesh were determined using gamma ray spectrometry. The outdoor and indoor external effective dose rates and the radiation hazard indices from these soil activities were evaluated. The dose rates were found to be about four times higher than the reported world average value. The concentration of natural radionuclides, derived radium equivalent activities and the representative level indices were also found to be higher. Recommendations on radiological and dosimetric measures have been suggested with an aim of minimising the harmful effects of ionising radiation to the population of the area concerned.

Background Radiation↗

Evaluation of absorbed dose rate and annual effective dose equivalent due to terrestrial gamma radiation in rocks in a part of Southwestern Nigeria.

The average outdoor absorbed dose rate in air and the average annual effective dose equivalent due to terrestrial gamma radiation from 40K, 238U and 232Th in rocks in Ondo and Ekiti States, Southwestern Nigeria have been evaluated from measurements of the concentrations of these radionuclides in this environmental material. The concentration measurements were obtained using a very sensitive gamma spectroscopic system consisting of a 7.6 cm x 7.6 cm NaI(Tl) scintillation detector coupled to a computerised ACCUSPEC installation. The average absorbed dose rate and average annual effective dose equivalent was found to be 8.33 +/- 2.76 nGy x h(-1) and 8.7 +/- 2.9 microSv x y(-1) respectively.

Background Radiation↗

Assessment of the natural radioactivity and its radiological hazards in Shewa-Shahbaz Garhi igneous complex, Peshawar Plain, NW Pakistan.

Forty-two representative rock samples used for construction purpose were collected from the quarries and outcrops of the rock units forming the Shewa-Shahbaz Garhi igneous complex, North-West Pakistan. Radioactivity of terrestrial radionuclides (238U, 232Th, and 40K) was measured in these samples using gamma ray spectrometry system with an HPGe detector. The samples showed fairly high mean concentrations of 51 +/- 16 Bq kg(-1) of 238U, 70 +/- 20 Bq kg(-1) of 232Th and 1,272 +/- 367 Bq kg(-1) of 40K. Mean absorbed gamma dose rate in air of 119 +/- 29 nGy h(-1) was found. Assessment of radiological hazards was made by calculating radium equivalent activities with external and internal hazard indices. The calculations showed radium equivalent activity ranging from 52 to 346 Bq kg(-1). External and internal hazard indices ranging from 0.14 to 0.94 and 0.17 to 1.1, respectively, were found.

Background Radiation↗