Search PubMed⌕ Search

PubMed · 16376224

Radiation: basic principles.

Abstract

This communication describes some basic principles of radiation that are relevant for understanding its use in vascular brachytherapy. It describes various characteristics of gamma-rays and beta-particles, including their interaction with matter such as tissues. It also explains different terms and concepts such as radioactivity, half-life, absorbed dose, range which would help the brachytherapy practitioners appreciate the physics aspects of the therapy.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Kishor Mehta. 2005. Radiation: basic principles.. https://doi.org/10.1016/j.jvs.2005.08.022

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A plastic scintillation dosimeter for high dose rate brachytherapy.

In vivo dose verification in brachytherapy requires a small insertable dosimeter with a real-time readout capability. Fibre optic scintillation dosimeters, consisting of a plastic scintillator coupled to an optical fibre, are one of the most promising dosimeters for this application. We have developed two sizes of the BrachyFOD scintillation dosimeter which have external diameters of 2.2 mm and 1 mm and have determined their important dosimetric characteristics (depth dose relation, angular dependence, temperature dependence, energy dependence). We have shown that the background signal created by Cerenkov and fibre fluorescence does not significantly affect the performance in most clinical geometries using an (192)Ir source from an HDR brachytherapy unit. The dosimeter design enables readout at less than 0.5 s intervals. The BrachyFOD satisfies the need for a real-time in vivo brachytherapy dosimeter.

Brachytherapy↗

Quality assurance of I-125 seeds for prostate brachytherapy using an imaging plate.

PURPOSE: OncoSeed is delivered in a sterile environment in the form of a cartridge, so it is impractical to resterilize and reload seeds after calibration. We investigated a new method using an imaging plate dosimetry system to characterize all seeds in the OncoSeed cartridge in a sterile environment. METHODS AND MATERIALS: Seeds within the cartridge were placed on an imaging plate, and the imaging plate irradiated. To remove scatter radiation, and improve spatial resolution of seed images, we used X-ray parallel cross grids. The irradiated imaging plate was scanned using a Bio-imaging Analyzer System, and radioactivity intensities of seed images were given in counts. Counts could be translated to profiles, and each seed within the cartridge was analyzed. RESULTS: Results showed a good correlation between counts and total radioactivity of the seeds within the cartridge. Thus, using a least-squares line, it was possible to characterize a cartridge with unknown apparent activity. By analyzing the profiles, it was possible not only to detect a miscalibrated seed in the cartridge from its relative difference in counts, but also to identify its position in the cartridge. No significant changes in counts were seen between sterile and nonsterile environments. CONCLUSION: Using an imaging plate dosimetry system, all seeds in a cartridge could be characterized in a sterile environment.

Brachytherapy↗