A microfluidic SELEX prototype.

Abstract

Aptamers are nucleic acid binding species capable of recognizing a wide variety of targets ranging from small organic molecules to supramolecular structures, including organisms. They are isolated from combinatorial libraries of synthetic nucleic acid by an iterative process referred to as SELEX (Systematic Evolution of Ligands by Exponential Enrichment). Here we describe an automated microfluidic, microline-based assembly that uses LabView-controlled actuatable valves and a PCR machine, and which is capable of the selection and synthesis of an anti-lysozyme aptamer as verified by sequence analysis. The microfluidic prototype described is 1) a simple apparatus that is relatively inexpensive to assemble, making automated aptamer selection accessible to many investigators, and 2) useful for the continued "morphing" of macro-->meso-->microfabricated structures until a convergence to a few functional systems evolves and emerges, partly or completely achieving simpler, smaller and more rapid SELEX applications.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Glen Hybarger, Joseph Bynum, Robert F Williams, James J Valdes, James P Chambers. 2005-11-29. A microfluidic SELEX prototype.. https://doi.org/10.1007/s00216-005-0089-3

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Comparison of oligonucleotide migration in a bicontinuous cubic phase of monoolein and water and in a fibrous agarose hydrogel.

Porous hydrogels such as agarose are commonly used to analyze DNA and water-soluble proteins by electrophoresis. More recently lyotropic liquid crystals, such as the diamond cubic phase formed by the lipid monoolein and water, has become a new type of well-defined porous structure of interest for both hydrophilic and amphiphilic analytes. Here we compare these two types of matrixes by investigating the nature of retardation they confer to an oligonucleotide that migrates in their respective aqueous phases. The retardation for a 25-mer oligonucleotide was found to be about 35-fold stronger in the cubic phase than in an agarose hydrogel modified to have the same average pore size. According to modelling, the strong retardation is primarily due to the fact that hydrodynamic interaction with the continuous monoolein membrane is a stronger source of friction than the steric interactions (collisions) with discrete gel fibres. A secondary effect is that the regular liquid crystal has a narrower pore-size distribution than the random network of the agarose gel. In agreement with experiments, these two effects together predict that the retardation in the cubic phase is a 30-fold stronger than in an agarose gel with the same average pore radius.

Electrophoresis, Agar Gel↗

Can lithium-heparin plasma be used for protein electrophoresis and paraprotein identification?

INTRODUCTION: Lithium-heparin plasma is the most commonly used sample type in many hospitals, but it has been suggested that it is not suitable for protein electrophoresis due to the presence of fibrinogen, which can potentially mask a paraprotein band or be misconstrued as one. Here we aimed to demonstrate that lithium-heparin plasma samples could be used for protein electrophoresis and paraprotein typing without or with ethanol treatment to remove the fibrinogen. METHOD: A lithium-heparin sample from a patient with IgGlambda, IgGkappa, IgAlambda and IgAkappa myeloma, a non-specific polyclonal increase and a serum control were treated with ethanol prior to protein electrophoresis. Immunofixation electrophoresis was undertaken to investigate the effect of ethanol treatment on immunoglobulin and light chains. Nephelometry was undertaken to investigate whether ethanol treatment affected the quantification of IgG levels. Densitometric evaluation of proteins after electrophoresis was used to study whether ethanol treatment affected other serum proteins. An audit was also undertaken to ascertain the magnitude of the potential interference from the fibrinogen band in heparinized samples. RESULTS AND CONCLUSIONS: Ethanol treatment significantly but incompletely removed the fibrinogen in lithium-heparin plasma samples and did not affect the integrity of any of the proteins investigated. Even without ethanol treatment, lithium-heparin plasma can be used for protein electrophoresis and paraprotein identification as the instances of interference between fibrinogen and paraproteins was low (2.3%). In rare cases where there is uncertainty or ambiguity, immuno-fixation electrophoresis is recommended. This report has implications in terms of reducing costs and turn-around time as it prevents the need for requesting another serum sample from patients. This may be one step towards a universal sample for all tests.

Electrophoresis, Agar Gel↗

Sodium dodecyl sulfate agarose gel electropheresis and electroelution of high molecular weight human salivary mucin.

The aim of this study was to test the applicability of sodium dodecyl sulfate (SDS) agarose gel electrophoresis, electroelution and electrophoretic filtration as methods of separation, detection, and purification of high molecular weight human salivary mucin. SDS agarose gel electrophoresis of whole saliva and mucin prepared by density gradient ultracentrifugation revealed bands with molecular weights in excess of 450 kDa and between 1.6x10(6) and 2x10(6) Da. Electroelution of material from gel and subsequent electrophoresis resulted in highly purified high molecular weight material. Electrophoretic filtration, a method of collecting the material remaining from whole saliva in the slot after penetration of low molecular weight constituents into SDS polyacrylamide gel, failed to produce pure high molecular weight material. It is concluded that SDS agarose gel electrophoresis and electroelution are suitable methods for studying high molecular weight salivary mucin glycoproteins.

Electrophoresis, Agar Gel↗