Search PubMed⌕ Search

PubMed · 16297240

A stepwise framework for the normalization of array CGH data.

Abstract

BACKGROUND: In two-channel competitive genomic hybridization microarray experiments, the ratio of the two fluorescent signal intensities at each spot on the microarray is commonly used to infer the relative amounts of the test and reference sample DNA levels. This ratio may be influenced by systematic measurement effects from non-biological sources that can introduce biases in the estimated ratios. These biases should be removed before drawing conclusions about the relative levels of DNA. The performance of existing gene expression microarray normalization strategies has not been evaluated for removing systematic biases encountered in array-based comparative genomic hybridization (CGH), which aims to detect single copy gains and losses typically in samples with heterogeneous cell populations resulting in only slight shifts in signal ratios. The purpose of this work is to establish a framework for correcting the systematic sources of variation in high density CGH array images, while maintaining the true biological variations. RESULTS: After an investigation of the systematic variations in the data from two array CGH platforms, SMRT (Sub Mega base Resolution Tiling) BAC arrays and cDNA arrays of Pollack et al., we have developed a stepwise normalization framework integrating novel and existing normalization methods in order to reduce intensity, spatial, plate and background biases. We used stringent measures to quantify the performance of this stepwise normalization using data derived from 5 sets of experiments representing self-self hybridizations, replicated experiments, detection of single copy changes, array CGH experiments which mimic cell population heterogeneity, and array CGH experiments simulating different levels of gene amplifications and deletions. Our results demonstrate that the three-step normalization procedure provides significant improvement in the sensitivity of detection of single copy changes compared to conventional single step normalization approaches in both SMRT BAC array and cDNA array platforms. CONCLUSION: The proposed stepwise normalization framework preserves the minute copy number changes while removing the observed systematic biases.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Mehrnoush Khojasteh, Wan L Lam, Rabab K Ward, Calum MacAulay. 2005-11-18. A stepwise framework for the normalization of array CGH data.. https://doi.org/10.1186/1471-2105-6-274

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effect of the electrolyte concentration on cation binding in aqueous surfactant solutions.

Electrospray ionisation mass spectrometry (ESI-MS) is used for the qualitative and quantitative study of ion binding to interfaces. The ESI-MS measurements are carried out in aqueous solutions of sodium dodecyl sulphate (SDS) in the presence of NaCl, NH(4)ClO(4) , KCl, or Mg(ClO(4))(2) . The effect of the electrolyte concentration on the fractions, y(cation(+) ), of the DS(-) monomers bound to the cations is shown. Moreover, the binding stability of different cations with DS(-) monomers is determined versus the electrolyte concentration. This stability and the y(Na(+) ) values (the Na(+) ions derived from SDS), estimated in the presence of a given electrolyte, are quantitatively correlated with the electrolyte cation effect on the water structure. We also present calibration curves from which the molar concentrations of the sodium ions (derived from SDS) and of the other cations (derived from the electrolyte), bound to the SDS-micelle surface at a given electrolyte concentration, can be obtained. Besides, specific ion effects (Hofmeister effects) are considered for 1:1 electrolytes.

Calibration↗

Development of NIRS equations for food grain quality traits through exploitation of a core collection of cultivated sorghum.

A sorghum core collection representing a wide range of genetic diversity and used in the framework of a sorghum breeding and genetics program was evaluated by near-infrared reflectance spectroscopy (NIRS) to predict food grain quality traits: amylose content (AM), protein content (PR), lipid content (LI), endosperm texture (ET), and hardness (HD). A total of 278 sorghum samples were scanned as whole and ground grain to develop calibration equations. Laboratory analyses were performed on NIRS sample subsets that preserved the core collection racial distribution. Principal component analysis performed on NIRS spectra evidenced a level of structure following known sorghum races, which underlined the importance of using a wide range of genetic diversity. Performances of calibration equations were evaluated by the coefficient of determination, bias, standard error of laboratory (SEL), and ratio of performance deviation (RPD). Ground grain spectra gave better calibration equations than whole grain. PR equation (RPD of 5.7) can be used for quality control. ET, LI, and HD equations (RPD of 2.9, 2.6, and 2.6, respectively) can be used for screening steps. Even with a small SEL in whole sample analysis, a RPD of 1.8 for AM confirmed that this variable is not easy to predict with NIRS.

Calibration↗

Purification and characterization of a biosurfactant produced by Pseudomonas sp. G11 by asymmetrical flow field-flow fractionation (AsFlFFF).

Three hundred and thirty two bacterial colonies were isolated from soil contaminated by an oil spill. All the bacteria were cultured in a liquid medium individually, and the surface tensions of the media were compared. The bacterium whose culture medium had the lowest surface tension was identified as Pseudomonas sp. G11. A biosurfactant was produced by cultivation of the Pseudomonas sp. G11 in the LB media. For extraction of the biosurfactant, two solvent systems were used (n-hexane and a 2:1 (v/v) mixture of chloroform/MeOH), and the results were compared. Various experimental conditions (solvent composition, flow rate, etc.) were tested to optimize the analysis of the biosurfactant by asymmetrical flow field-flow fractionation (AsFlFFF). The biosurfactant was successfully separated from the culture medium by AsFlFFF when pure water was used as the carrier. From the retention data, the hydrodynamic diameter (dH) and molecular weight (M) of the biosurfactant were determined by AsFlFFF. The molecular weight was determined by using pullulans as the calibration standards. The dH and M were 49 nm and 2.3 x 10(5) Da when extracted with n-hexane, and 39 nm and 1.13 x 10(5) Da when extracted with the 2:1 mixture of chloroform/MeOH, respectively.

Calibration↗