Search PubMed⌕ Search

PubMed · 16295597

Zero fire tolerance.

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Sam Poddar. Zero fire tolerance.. https://doi.org/10.7748/ns.20.8.32.s36

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Experimental study of thin-layer boilover in large-scale pool fires.

By performing a series of pool fire experiments, the authors attempt to apply knowledge of thin-layer boilover to the large scale (pool diameter from 1.5 to 6 m). Two commercial hydrocarbons were used: gasoline and diesel. As expected, only in the case of diesel did the phenomenon of thin-layer boilover occur. Data were used to analyze various features of thin-layer boilover in fires, particularly its intensity and onset time. A comparison with results published in the literature shows the importance of this study.

Fires↗

The impact of various rehydration volumes for firefighters wearing protective clothing in warm environments.

This study examined different fluid replacement quantities during intermittent work while wearing firefighting protective clothing and self-contained breathing apparatus in the heat (35 degrees C, 50% relative humidity). Twelve firefighters walked at 4.5 km per h with 0% elevation on an intermittent work (50 min) and rest (30 min) schedule until they reached a rectal temperature of 39.5 degrees C during work periods and 40.0 degrees C during rest, heart rates of 95% of maximum and/or exhaustion. During the heat-stress trials subjects received one of four fluid replacement quantities, high (H), moderate (M), low (L), and no hydration (NH), where H, M and L represented 78%, 63% and 37% of fluid loss, respectively. The total tolerance time (work + rest) was significantly greater during H (111.8 +/- 3.5), M (112.9 +/- 5.2) and L (104.2 +/- 5.8) compared to NH (95.3 +/- 3.8). In addition, work time (min), which excluded rest periods, was significantly greater in H (82.6 +/- 3.5), and M (82.9 +/- 5.2) compared to NH (65.3 +/- 3.8). It is concluded that incorporating even partial fluid replacement strategies while wearing firefighting protective clothing and self-contained breathing apparatus in the heat improves tolerance time.

Fires↗

Model of large pool fires.

A two zone entrainment model of pool fires is proposed to depict the fluid flow and flame properties of the fire. Consisting of combustion and plume zones, it provides a consistent scheme for developing non-dimensional scaling parameters for correlating and extrapolating pool fire visible flame length, flame tilt, surface emissive power, and fuel evaporation rate. The model is extended to include grey gas thermal radiation from soot particles in the flame zone, accounting for emission and absorption in both optically thin and thick regions. A model of convective heat transfer from the combustion zone to the liquid fuel pool, and from a water substrate to cryogenic fuel pools spreading on water, provides evaporation rates for both adiabatic and non-adiabatic fires. The model is tested against field measurements of large scale pool fires, principally of LNG, and is generally in agreement with experimental values of all variables.

Fires↗