Search PubMed⌕ Search

PubMed · 16276430

Computer-aided interactive indirect bonding.

Abstract

INTRODUCTION: The introduction of the virtual occlusal set-up, limited to the permanent dentition with dento-dental and dento-alveolar discrepancies, based on the straight wire technique with final arches .020" x .025" ss in straight wire brackets .022" x .028" is an evolution of the 3D digital model with clinical impact. AIM: To present a computer-aided solution to orthodontic indirect bonding, allowing accurate positioning of straight-wire brackets based on a virtual occlusal set-up resulting from the treatment plan. MATERIAL AND METHODS: Computer-aided indirect bonding was applied in two cases: a Class II patient in the permanent dentition, crowding, rotation of upper and lower bicuspids and a Class I patient in the permanent dentition with already extracted 1.4, 2.4, 3.4, 4.4, severe crowding, rotation, arch form reduction. Speed brackets were utilized in both cases. RESULTS: In the first case the brackets' starting position on the patient corresponds to the final position on the virtual occlusal set-up. In the second case the resulting occlusion at the end of treatment corresponds to the final occlusion on the virtual occlusal set-up. DISCUSSION: The computerized tools employed in the process enabled precise bracket placement on the stone model. An algorithm from the virtual set-up is the determinant for the precision. CONCLUSION: Computer aided indirect bonding is a method of placing brackets precisely.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Francesco Garino, G Battista Garino. 2005. Computer-aided interactive indirect bonding.. https://pubmed.ncbi.nlm.nih.gov/16276430/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Rational and efficient geometric definition of pharmacophores is essential for the patent process.

The geometric description of pharmacophores suffers from approximations. No consensus has been clearly established, despite the increasing interest in using pharmacophores in drug design and in patent applications. We therefore propose an original definition of a pharmacophore using spherical coordinates. These coordinates give a precise description of each point using three parameters: distance to a geometric origin and two angles. If necessary, these parameters can be easily and rapidly converted to cartesian coordinates. Our method can guarantee, to the patent applicant, the safe protection of his intellectual property by both improving markedly the readability of a pharmacophore definition and bringing, to the person who is skilled in the art, enough information to understand easily the essence of the invention.

Computer-Aided Design↗

Shape Signatures: speeding up computer aided drug discovery.

Identifying potential lead molecules is becoming a more automated process. We review Shape Signatures, a tool that is effective and easy to use compared with most computer aided drug design techniques. Laboratory researchers can apply this in silico technique cost-effectively without the need for specialized computer backgrounds. Identifying a potential lead molecule requires database screening, and this becomes rate-limiting once the database becomes too large. The use of Shape Signatures eliminates this concern and offers molecule screening rates that are in advance of any currently available method. Shape Signatures provides a conduit for researchers to conduct rapid identification of potential active molecules, and studies with this tool can be initiated with only one bioactive lead or receptor site.

Computer-Aided Design↗

Waveguide analysis of heat-drawn and chemically etched probe tips for scanning near-field optical microscopy.

We analyze two basic aspects of a scanning near-field optical microscope (SNOM) probe's operation: (i) spot-size evolution of the electric field along the probe with and without a metal layer, and (ii) a modal analysis of the SNOM probe, particularly in close proximity to the aperture. A slab waveguide model is utilized to minimize the analytical complexity, yet provides useful quantitative results--including losses associated with the metal coating--which can then be used as design rules.

Computer-Aided Design↗