Search PubMed⌕ Search

PubMed · 16200527

Capillary-based solid-phase extraction with columns prepared using different bead trapping methods.

Abstract

Three approaches of bead immobilization for CEC column preparation in a capillary were examined for SPE. The three approaches included a packed column with a single frit, a packed column with an inlet and outlet frit, and an entrapped column where beads were immobilized within an organic polymer. A direct comparison of SPE/preconcentration of 4,4-difluoro-1,3,5,7,8-pentamethyl-4-bora-3a,4a-diaza-s-indacene and 4,4-difluoro-5,7-dimethyl-4-bora-3a,4a-diaza-s-indacene-3-propionic acid with a 2 cm long bed showed that the entrapped column yielded the best performance in terms of reproducibility and robustness. The room temperature chemistry utilized to form the entrapped column enables the column to be photopatterned anywhere within the capillary without loss in bead functionality, and effectively links individual beads to one another at specific bead-bead and bead-capillary contact points. A 0.5 cm long entrapped bed exhibits high mechanical strength and is able to withstand >4400 psi. The entrapped bed was used to preconcentrate progesterone and beta-estradiol providing signal enhancements of >600. Following preconcentration, the hormones could be separated using CEC. With the current availability of numerous well-characterized chromatographic packing materials and the relative simplicity of the fabrication method, this methodology can be readily adapted to HPLC, CEC, and micro total analysis system.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ruixi Xie, Richard Oleschuk. 2005. Capillary-based solid-phase extraction with columns prepared using different bead trapping methods.. https://doi.org/10.1002/elps.200500215

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A novel relationship between time offsets in capillary electrophoresis and DNA sequence variations in short tandem repeats.

Next-generation sequencing (NGS) provides increased discriminatory power in forensic DNA analysis due to the detection of isoalleles. Differences in sequences between alleles allow for a second layer of differentiation between DNA contributors beyond the number of short tandem repeat (STR) repeat units. However, because NGS is a more time and resource-intensive analysis than conventional capillary electrophoresis (CE), laboratories may benefit from indicators that suggest NGS is likely to provide added value. This study examined whether CE migration offsets, measured as residuals in the OSIRIS analysis software, can differ significantly among STR isoalleles. Residuals represent the time offset between a sample allele peak and its corresponding allelic ladder peak. Paired CE and NGS data from 95 single source samples were analyzed for CE-based residual differences, as the NGS data provided the sequence information of the corresponding isoalleles. Residual values differed significantly among isoalleles at several STR loci. Statistically significant differences were identified at D16S539 and D3S1358, as well as at specific allele lengths within D12S391, D13S317, and D8S1179. These findings demonstrate that CE residual variation can reflect underlying STR sequence differences between contributors. In practice, residual-based metrics could help laboratories to identify casework reference samples where NGS is likely to provide additional discrimination, without the need for processing outside of a routine CE workflow. Due to the potentially large number of isoalleles, community wide efforts to aggregate CE residual differences versus isoallele sequences may be useful in the validation and implementation of this approach to add value to forensic DNA analyses.

Electrophoresis, Capillary↗

Electrophoretic analysis of proteins and enantiomers using capillaries modified by a successive multiple ionic-polymer layer (SMIL) coating technique.

The applicability of three-layer coatings consisting of three different polymers (A(+)-B(-)-C(+) coating) prepared by a successive multiple ionic-polymer layer (SMIL) coating technique to the immobilization of polypeptides and/or proteins onto the inner surface of the capillaries was investigated to provide a high-performance separation medium for proteins and enantiomers in capillary electrophoresis (CE). To obtain a stable protein-coated capillary, high molecular mass poly(ethyleneimine) (PEI) was employed as the first layer in the A(+)-B(-)-C(+) coating, and then a cationic protein was immobilized as the third layer. Comparisons of analytical performances between the A(+)-B(-)-C(+) coating and the conventional SMIL-coated (A(+)-B(-)-A(+) coating) capillary were conducted. The CE separation of cationic proteins was successfully achieved with the prepared capillaries. In addition, the polypeptide- and protein-coated capillaries were applied to the chiral separation of a binaphthyl compound. It should be noted that the chiral separation efficiency was strongly dependent on the second anionic polymer layer of the coating. Effects of the interaction between oppositely charged ionic polymer layers on the separation efficiency are discussed.

Electrophoresis, Capillary↗

UV embossed polymeric chip for protein separation and identification based on capillary isoelectric focusing and MALDI-TOF-MS.

This paper demonstrates a ultraviolet (UV)-embossed polymeric chip for protein separation by capillary isoelectric focusing (CIEF) and identification by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS). The polymeric chip was replicated by a UV-embossing technique using a soft rubber mold. Five diverse widely investigated families of UV-cured formulations were examined for MALDI ionization efficiency of bovine serum albumin (BSA) samples spotted on the polymer surfaces. The signal and signal-to-noise ratio from the polyester formulation were each 12 times those obtained with PMMA (a commonly used polymer material for MALDI) at picomole sample concentration. A polyester chip was successfully used to carry out CIEF to separate proteins, followed by MALDI-TOF-MS identification. Issues related to the successful chip fabrication and protein separation and identification are discussed.

Electrophoresis, Capillary↗