Most temperature measurements are not so much concerned with absolute accuracy as repeatability, since focused on is whether the temperature is stable, moving up or moving down and by what rate of change. This is not the case, however, with temperature measurement within sterilisers, stresses Ted Baker, managing director, Isopharm Sentry.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ted Baker. 2005. Measurement system errors explained.. https://pubmed.ncbi.nlm.nih.gov/16163866/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Comparative study of surgical instruments from sterile-service departments for presence of residual gram-negative endotoxin and proteinaceous deposits.

The ineffective cleaning of surgical instruments may be a vector for the transmission of hospital-acquired infections. The aim of this research was to investigate whether further decontamination procedures need to be instigated in sterile-service departments (SSDs) to reduce the risk of nosocomial illnesses, such as endotoxemia, sepsis, or iatrogenic Creutzfeldt-Jakob disease (to date, 1,147 cases of confirmed Creutzfeldt-Jakob disease deaths in the United Kingdom since 1990 have been reported). Instrument sets were obtained from nine anonymous United Kingdom National Health Service (NHS) primary care trust SSDs. The investigation implemented an advanced light microscopy technique, episcopic differential interference contrast microscopy with the sensitive fluorescent reagents SYPRO Ruby and 4',6-diamidino-2-phenylindole dihydrochloride (DAPI), to detect proteinaceous and microbial contamination levels. Gram-negative lipopolysaccharide (LPS) endotoxin was monitored using a dansylated polymyxin B fluorochrome agent. None of the 260 instruments examined displayed signs of microbial colonization or LPS endotoxin contamination. However, over 60 percent of the instruments showed a high degree of protein soiling (0.4 to 4.2 mug protein/mm(2)). Some instruments appeared soiled with crystalline deposits that may consist of a potentially hazardous material contributing to inflammation and/or surgical shock. It is clear that the overall standard for cleaning must be raised in order to fulfill the imminent introduction of new European standards and to reduce the risk of cross-patient contamination and iatrogenic transmission.

Decontamination↗

Soil organic matter-hydrogen peroxide dynamics in the treatment of contaminated soils and groundwater using catalyzed H2O2 propagations (modified Fenton's reagent).

The interactions between catalyzed H(2)O(2) propagations (CHP-i.e. modified Fenton's reagent) and soil organic matter (SOM) during the treatment of contaminated soils and groundwater was studied in a well-characterized surface soil. The fate of two fractions of SOM, particulate organic matter (POM) and nonparticulate organic matter (NPOM), during CHP reactions was evaluated using concentrations of hydrogen peroxide from 0.5 to 3M catalyzed by soluble iron (III), an iron (III)-ethylenediamine tetraacetic acid (EDTA) chelate, or naturally-occurring soil minerals. The destruction of total SOM in CHP systems was directly proportional to the hydrogen peroxide dosage, and was significantly greater at pH 3 than at neutral pH; furthermore, SOM destruction occurred predominantly in the NPOM fraction. At pH 3, SOM did not affect hydrogen peroxide decomposition rates or hydroxyl radical activity in CHP reactions. However, at neutral pH, increasing the mass of SOM decreased the hydrogen peroxide decomposition rate and increased the rate of hydroxyl radical generation in CHP systems. These results show that, while CHP reactions destroy some of the organic carbon pools, SOM does not have a significant effect on the CHP treatment of soils and groundwater.

Decontamination↗

Surface decontamination of surgical instruments: an ongoing dilemma.

The issues of cross-infection and the survival of variant Creutzfeldt Jakob disease (vCJD) on surgical instruments have highlighted the importance of cleanliness of multiple-use surgical instruments. The aim of this study was to assess the levels of total protein contamination on a wide range of surgical instruments as an indication of the effectiveness of routine cleaning and disinfection in hospitals. Anonymized trays of wrapped and autoclaved instruments were supplied to two laboratories for analysis at the stage where they would normally be returned to operating theatres. Instruments were assessed for residual protein and total organic matter. Laboratory A showed that 17% (35/206) of instruments were above a threshold that equated to 200 microg. The worst examples, a McIvor gag, a Draffin rod (child) and a Yankaur sucker, had 1.028, 1.286 and 2.228 mg of extractable protein, respectively. The median (25th, 75th percentiles) amount of protein from instruments from different hospitals assessed in Laboratory B ranged from 8 (3, 30)mug (Hospital C) to 91 (35, 213) mug (Hospital D) (P=0.044). The residual matter washed from instruments varied from 0.62 (0.32, 0.81) mg (Hospital E) to 3.5 (3.5, 4.0) mg (Hospital A) (P=0.0001). In one case, 45 mg of residual organic matter was washed from an instrument (split stem). In conclusion, this study demonstrated that a proportion of instruments at the point of use show levels of protein that could pose a direct cross-infection risk via prion agents and other organic contamination that may reduce the effectiveness of cleaning/disinfection strategies targeted against either prions or traditional infectious agents.

Decontamination↗