Search PubMed⌕ Search

PubMed · 16119026

Prerequisites for proper curing.

Abstract

The prerequisites for proper curing include: 1) sufficient light intensity at 2) a certain wavelength, for 3) a certain time interval. This review discusses the radial output by halogen, PAC and LED lights, and the adaption of this output to meet the wavelength prerequisites for optimum polymerisation. Some basic terminology relating to the power of the light and intensity is explained and calculations are used to illustrate to the reader how the size of the light guide increases or reduces the intensity of the light beam.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

C Strydom. 2005. Prerequisites for proper curing.. https://pubmed.ncbi.nlm.nih.gov/16119026/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effect of cyclic loading and environmental aging on the fracture toughness of dental resin composite.

OBJECTIVE: The main purpose of this study was (1) to investigate the effects of cyclic loading and environmental aging on three dental resin composites with different filler compositions: a fiber filler, a hybrid filler, and a microfill; and (2) to predict fracture in dental resin composite under mixed-mode loading conditions. METHODS: Diametral disk specimens 25 mm in diameter and 2 mm in thickness were used in this study. Two methods were used for generating initial cracks in the specimen. The first method involved machining a 3-mm notch in the center of the disk specimens, and then the notch tips were sharpened with a 0.2-mm-diameter jeweler's saw blade. In the second method for obtaining sharper crack tips, a three-way wedge was forced into a 3.175-mm hole drilled in the center of the specimen, resulting in sharp cracks emanating from the notch tips. CYCLIC TESTS: The specimens were aged for 4 months in air, water, artificial saliva, and a 50/50 (by volume) mixture of ethanol and water at room temperature in sealed polyethylene containers. Both unaged and aged specimens (5 specimens for each variable) were subjected to cyclic loading at a frequency of 5 Hz with sinusoidal loads cycling for 1, 1000, and 100,000 cycles at a load level approximately 60% of the fracture load for noncycled specimens. Following load cycling, the specimens were tested in compression in a displacement-controlled loading mode at a loading rate of 1.27 mm/min. RESULTS: Test results show that aging in a 50/50 alcohol-water mixture lowered the fracture toughness of dental resin composite, which was further reduced by cyclic loading. MIXED-MODE TESTS: The maximum tensile stress (MTS) criterion was used to predict fracture in dental resin composite under mixed-mode loading conditions. The loads at failure were used as input into a finite element model. After obtaining the stress field in the specimens by the finite element method, the mixed-mode stress intensity factors were calculated using an interaction energy integral method. RESULTS: Good agreement was obtained between the fracture envelope predicted by the MTS criterion and the experimental fracture toughness data. Hence, it can be concluded that it is only necessary to characterize the mode I fracture toughness to fully characterize the mixed-mode behavior of the dental resin composites that were considered in the present study.

Composite Resins↗

Bonding characteristics of newly developed all-in-one adhesives.

This study evaluated the microtensile bond strength and the interfacial morphology of newer adhesives. The occlusal surfaces of extracted teeth were ground flat for random allocation to four equal groups. Resin composite was bonded to each surface using either Clearfil SE Bond [SEB], Clearfil Protect Bond [PB], G-Bond [GB], or an experimental adhesive, SSB-200 [SSB]. After storage for 24 h in water at 37 degrees C, they were sectioned into beams (cross-sectional area 1 mm(2)) for microtensile bond strength testing (muTBS) at a crosshead speed of 1 mm/min. The load at failure of each was recorded; the data were analyzed by one-way ANOVA and Games Howell tests. The surfaces of the fractured specimens were observed using SEM. For the ultra-morphology of the interface, the occlusal surfaces of four more teeth were prepared as before and a thin layer of flowable resin composite was bonded to each surface using one of the four adhesives. The mean muTBS ranged from 39.68 MPa (GB) to 64.97 MPa (SEB). There were no statistical differences between SEB and SSB, or between PB and GB (p > 0.05). The muTBS of SEB and SSB were significantly greater than that of PB and GB (p < 0.05). SEMs of the fractured surfaces revealed a mixed (cohesive/interfacial) failure. TEM examination highlighted differences in the hybrid layer; SEB had a thicker layer than the others. In conclusion, the newer all-in-one adhesives produced a thin hybrid layer but varied in their bond strengths. The 2-step self-etching adhesives do not necessarily produce higher bond strengths than that of the all-in-one systems.

Composite Resins↗

Mutual wear evaluation of resin composites when opposing enamel and dentin.

Mutual wear rates of resin composites and both superficial and deep layers of enamel and dentin were investigated by means of an in vitro wear test. Occlusal surfaces of extracted molars were ground flat to respective layers of enamel and dentin. Hemispherical-shaped styli (n = 8) made of microfilled and microhybrid composites were placed perpendicular to the finished tooth surface (600 grit) in the presence of tap water, and a two-body wear test (75 N load and 1.2 Hz) was performed for 100,000 cycles. The wear depths on both tooth and composite specimens were determined, and the data were statistically analyzed by two-way ANOVA and Boneferroni test (p < 0.05). The values of deep and superficial dentin specimens against Esthet-X (530.2 +/- 213.0 microm and 717.4 +/- 309.6 microm) were significantly greater than those against Epic-TMPT (34.1 +/- 17.6 microm and 29.3 +/- 10.8 microm). The values of Esthet-X against dentin were the smallest (2.4-2.6 microm), followed by those of the same material against enamel (5.5-6.1 microm), and those of Epic-TMPT against enamel (7.2-7.9 microm). It was concluded that the wear rates of dentin varied with the type of composite used while those of enamel showed the consistency.

Composite Resins↗