Search PubMed⌕ Search

PubMed · 16053279

Fiber-optic microsensor array based on fluorescent bulk optode microspheres for the trace analysis of silver ions.

Abstract

An optical microsensor array is described for the rapid analysis of silver ions at low parts per trillion levels. Because the ionophore o-xylylenebis(N,N-diisobutyldithiocarbamate) (Cu-I) was reevaluated and shown to exhibit excellent selectivity for silver ions, ion-selective electrode (ISE) membranes were optimized and found to exhibit the lowest reported detection limit so far (3 x 10(-10) M). A corresponding Ag+-selective fluorescent optical microsensor array for the rapid sensing of trace level Ag+ was then developed. It was fabricated using plasticized PVC-based micrometer-scale fluorescent microspheres that were produced via a sonic particle casting device. They contained 156 mmol/kg Cu-I, 10 mmol/kg 9-(diethylamino)-5-[4-(15-butyl-1,13-dioxo-2,14-dioxanodecyl) phenylimino]benzo[a]phenoxazine (chromoionophore VII, ETH 5418), 2.3 mmol/kg 1,1' '-dioctadecyl-3,3,3',3'-tetramethylindocarbocyanine perchlorate (internal reference dye), and 14 mmol/kg sodium tetrakis[3,5-bis(trifluoromethyl)phenyl]borate and were deposited onto the etched distal end of a 3200-microm-diameter optical fiber bundle. The microarray was characterized by fluorescence spectroscopy in samples containing 10(-12)-10(-8) M AgNO3 at pH 7.4, with selectivity characteristics comparable to the corresponding ISEs. The response time of the microsensor array was found to be less than 15 min for 10(-9) M AgNO3, which is drastically shorter than earlier data on optode films (8 h) and corresponding ISEs (30 min). A detection limit of 4 x 10(-11) M for Ag+ was observed, lower than any previously reported optode or silver-selective ISE. The microsensor array was applied for measurement of free silver levels in buffered pond water samples.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Katarzyna Wygladacz, Aleksandar Radu, Chao Xu, Yu Qin, Eric Bakker. 2005-08-01. Fiber-optic microsensor array based on fluorescent bulk optode microspheres for the trace analysis of silver ions.. https://doi.org/10.1021/ac050856s

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Chemical images: technical approaches and issues.

Chemical mapping techniques using Raman microscopy are introduced, and using an example of a pharmaceutical tablet, the practical aspects of data collection and processing to produce a chemical image of the sample are detailed. Issues related to data processing, instrument standards, chemical image reportable errors, and the interpretation of chemical images are presented to encourage debate, develop solutions, and promote use in other challenging scientific applications. applications.

Calibration↗

Nondestructive determination of lignans and lignan glycosides in sesame seeds by near infrared reflectance spectroscopy.

Sesame (Sesamum indicum L.) contains abundant lignans including lipid-soluble lignans (sesamin and sesamolin) and water-soluble lignan glycosides (sesaminol triglucoside and sesaminol diglucoside) related to antioxidative activity. In this study, near infrared reflectance spectroscopy (NIRS) was used to develop a rapid and nondestructive method for the determination of lignan contents on intact sesame seeds. Ninety-three intact seeds were scanned in the reflectance mode of a scanning monochromator. This scanning procedure did not require the pulverization of samples, allowing each analysis to be completed within minutes. Reference values for lignan contents were obtained by high-performance liquid chromatography analysis. Calibration equations for lignans (sesamin and sesamolin) and lignan glycosides (sesaminol triglucoside and sesaminol diglucoside) contents were developed using modified partial least squares regression with internal cross-validation (n = 63). The equations obtained had low standard errors of cross-validation and moderate R2 (coefficient of determination in calibration). The prediction of an external validation set (n = 30) showed significant correlation between reference values and NIRS predicted values based on the SEP (standard error of prediction), bias, and r2 (coefficient of determination in prediction). The models developed in this study had relatively higher values (more than 2.0) of SD/SEP(C) for all lignans and lignan glycosides except for sesaminol diglucoside, which had a minor amount, indicating good correlation between the reference and the NIRS estimate. The results showed that NIRS, a nondestructive screening method, could be used to rapidly determine lignan and lignan glycoside contents in the breeding programs for high quality sesame.

Calibration↗

Comparative uptake, metabolism, and utilization of menaquinone-4 and phylloquinone in human cultured cell lines.

It is generally accepted that the availability of vitamin K in vivo depends on its homologues, the biological activities of which would differ among organs. To test this hypothesis, we examined the uptake, metabolism, and utilization of menaquinone-4 (MK-4) and phylloquinone (PK) using 18O-labeled compounds in two cultured human cell lines (HepG2 and MG-63). Lipid extracts were prepared from the cells and media after 1, 3, and 6h of incubation. The detection of the vitamin K analogues (18O-, 16O-quinone, and epoxide forms) was carried out with LC-APCI-MS/MS as previously reported. The 18O of vitamin K was replaced with atmospheric 16O2 during the formation of vitamin K epoxide with a carboxylative catalytic reaction. As a result, a significant difference was observed between MK-4 and PK in the amounts taken up into the cells. The 18O-labeled MK-4 was rapidly and remarkably well absorbed into the cells and metabolized to the epoxide form via a hydroquinone form as compared to the 18O-labeled PK. The difference in uptake of MK-4 and PK was not affected by treatment with warfarin although the metabolism of both compounds was markedly inhibited. This methodology should be utilized to clarify some of the actions of vitamin K in target cells and facilitate the development of new vitamin K drugs.

Calibration↗