Search PubMed⌕ Search

PubMed · 15990937

Gallbladder varices.

Abstract

Gallbladder varices are relatively rare ectopic varices in patients with portal hypertension. We present here a case of gallbladder varices accurately diagnosed by color Doppler sonography. A 51-year-old woman was admitted to our unit with recurrent esophageal varices bleeding due to extrahepatic portal vein occlusion after splenectomy. Bleeding was controlled by endoscopic band ligation and esophageal varices were eradicated after the second endoscopic session. Doppler imaging showed the existence of portal cavernoma and gallbladder varices. The close follow-up period after complete eradication of esophageal varices showed no enlargement of varices of the gallbladder or complications related to them. Color Doppler sonography is a valuable noninvasive imaging technique for assessment of portal hemodynamic profile in patients with portal cavernoma as well as useful in detecting gallbladder varices. Preoperative correct diagnosis of gallbladder varices should increase the surgeon's vigilance during biliary tract surgery in patients with portal hypertension in order to avoid hazardous complications.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Igor Mishin. 2005. Gallbladder varices.. https://pubmed.ncbi.nlm.nih.gov/15990937/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

In-vivo coronary flow profiling based on biplane angiograms: influence of geometric simplifications on the three-dimensional reconstruction and wall shear stress calculation.

BACKGROUND: Clinical studies suggest that local wall shear stress (WSS) patterns modulate the site and the progression of atherosclerotic lesions. Computational fluid dynamics (CFD) methods based on in-vivo three-dimensional vessel reconstructions have recently been shown to provide prognostically relevant WSS data. This approach is, however, complex and time-consuming. Methodological simplifications are desirable in porting this approach from bench to bedside. The impact of such simplifications on the accuracy of geometry and wall shear stress calculations has to be investigated. METHODS: We investigated the influence of two methods of lumen reconstruction, assuming circular versus elliptical cross-sections and using different resolutions for the cross-section reconstructions along the vessel axis. Three right coronary arteries were used, of which one represented a normal coronary artery, one with "obstructive", and one with "dilated" coronary atherosclerosis. The vessel volume reconstruction was performed with three-dimensional (3D) data from a previously validated 3D angiographic reconstruction of vessel cross-sections and vessel axis. RESULTS: The difference between the two vessel volumes calculated using the two evaluated methods is less than 1 %. The difference, of the calculated pressure loss, was between 2.5% and 8.5% for the evaluated methods. The distributions of the WSS histograms were nearly identical and strongly cross-correlated (0.91-0.95). The good agreement of the results was confirmed by a Chi-square test. CONCLUSION: A simplified approach to the reconstruction of coronary vessel lumina, using circular cross-sections and a reduced axial resolution of about 0.8 mm along the vessel axis, yields sufficiently accurate calculations of WSS.

Blood Flow Velocity↗

Cerebral perfusion changes during cataplexy in narcolepsy patients.

To localize cerebral perfusion differences during cataplexy, brain SPECT subtraction was performed between cataplexy and baseline awake period or REM sleep in patients with narcolepsy. During cataplexy, subtracted SPECT showed hyperperfusion in right amygdala, bilateral cingulate gyri, basal ganglia, thalami, premotor cortices, sensorimotor cortices, right insula, and brainstem, and hypoperfusion in prefrontal cortex and occipital lobe. This result suggests that cataplexy is produced by the activation of amygdalo-cortico-basal ganglia-brainstem circuit.

Blood Flow Velocity↗

Dynamic deformation and recovery response of red blood cells to a cyclically reversing shear flow: Effects of frequency of cyclically reversing shear flow and shear stress level.

Dynamic deformation and recovery responses of red blood cells (RBCs) to a cyclically reversing shear flow generated in a 30-microm clearance, with the peak shear stress of 53, 108, 161, and 274 Pa at the frequency of 1, 2, 3, and 5 Hz, respectively, were studied. The RBCs' time-varying velocity varied after the glass plate velocity without any time lag, whereas the L/W change, where L and W were the major and minor axes of RBCs' ellipsoidal shape, exhibited a rapid increase and gradual decay during the deformation and recovery phase. The time of minimum L/W occurrence lagged behind the zero-velocity time of the glass plate (zero stress), and the delay time normalized to the one-cycle duration remained constant at 8.0%. The elongation of RBCs at zero stress time became larger with the reversing frequency. A simple mechanical model consisting of an elastic linear element during a rapid elongation period and a parallel combination of elements such as a spring and dashpot during the nonlinear recovery phase was suggested. The dynamic response behavior of RBCs under a cyclically reversing shear flow was different from the conventional shape change where a steplike force was applied to and completely released from the RBCs.

Blood Flow Velocity↗