Search PubMed⌕ Search

PubMed · 15988934

Development of pupillography using image processing.

Abstract

PURPOSE: Pupillary examination is an important objective method to diagnose lesions of the anterior visual pathways. However, errors and faults may easily alter the interpretation and value of the test as it is highly dependent on the examiner's skills. Therefore, we tried to develop a pupillography which is independent of the examiner. METHODS: Hardware composed of a binocularly measuring instrument adapted for an infrared charge coupled device (CCD) was developed. Two arrays of infrared light emitting diodes (LED) were supplied in front of each of the subject's eyes. A microcontroller to modulate these LED was developed, as was software to save and analyze the pupil images. The hardware was able to deliver a light to either eye or to both eyes, and to change the time, frequency, and intensity of the stimulus. The software automatically analyzed the pupil size and location by image processing. Pupil size was calculated continuously. After artifact elimination, the response amplitudes of the pupils were determined for the right and left pupils. RESULTS: Pupillary images of size 320 x 240, at 30 frames/second, were saved and processed to evaluate the change of the actual pupil size and the velocity of pupillary response. CONCLUSIONS: A pupillography to measure, save and analyze the pupillary response using image processing was developed. Further detailed clinical studies with a large number of patients will be required to validate this new method.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

InBum Lee, Byunghun Choi, Kwang Suk Park, Sang Sik Kim, Jeong-Min Hwang. 2005. Development of pupillography using image processing.. https://doi.org/10.3341/kjo.2005.19.2.149

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A simple confocal fibre-optic laser method for intraocular lens power measurement.

PURPOSE: To develop novel confocal fibre-optic laser method (CFOLM) for accurate and objective measuring of the dioptric power of both positive and negative intraocular lenses (IOLs). METHODS: The CFOLM principle of operation is based on a simple apertureless single-mode fibre laser confocal design. The key element is a single-mode fibre coupler that serves simultaneously as a point light source (3-5 microm fibre diameter) used for the formation of a collimated Gaussian beam, and as a confocal point receiver that is highly sensitive to spatial displacements of the focused backreflectance laser emission. The basic CFOLM systems include IOL testing set-ups for the measurement of both positive and negative IOLs. RESULTS: The CFOLM designs provide high accuracy (<or=1 microm) in spatially locating the IOL focal point and in measuring the focal length in a broad range of both positive and negative powers including high-magnification IOLs with power greater than +/-20 D. We have tested various IOL samples with both positive (+5 to +30 D) and negative (-5 to -20 D) powers and we have obtained high levels of power testing repeatability estimated by a SD in the interval of 0.004-0.06/0.003-0.013 D and a relative error in the interval of 0.015-0.3/0.02-0.16%, for positive/negative IOLs, respectively. CONCLUSIONS: The presented IOL power testing method offers a simple, accurate, objective, quick, and relatively inexpensive approach for dioptric power measurement of positive and negative IOLs. It provides an independent source of IOL power measurement data and information for evaluating the effectiveness and safety of novel IOL products.

Diagnostic Techniques, Ophthalmological↗

Remote image based retinopathy of prematurity diagnosis: a receiver operating characteristic analysis of accuracy.

BACKGROUND/AIMS: Telemedicine offers potential to improve the accessibility and quality of diagnosis of retinopathy of prematurity (ROP). The aim of this study was to measure accuracy of remote image based ROP diagnosis by three readers using receiver operating characteristic (ROC) analysis. METHODS: 64 hospitalised infants who met ROP examination criteria underwent two consecutive bedside procedures: dilated examination by an experienced paediatric ophthalmologist and digital retinal imaging with a commercially available wide angle camera. 410 images from 163 eyes were reviewed independently by three trained ophthalmologist readers, who classified each eye into one of four categories: no ROP, mild ROP, type 2 prethreshold ROP, or ROP requiring treatment. Sensitivity and specificity for detection of mild or worse ROP, type 2 prethreshold or worse ROP, and ROP requiring treatment were determined, compared to a reference standard of dilated ophthalmoscopy. ROC curves were generated by calculating values for each reader at three diagnostic cut-off levels: mild or worse ROP (that is, reader was asked whether image sets represented mild or worse ROP), type 2 prethreshold or worse ROP (that is, reader was asked whether image sets represented type 2 prethreshold or worse ROP), and ROP requiring treatment. RESULTS: Areas under ROC curves ranged from 0.747-0.896 for detection of mild or worse ROP, 0.905-0.946 for detection of type 2 prethreshold or worse ROP, and 0.941-0.968 for detection of ROP requiring treatment. CONCLUSIONS: Remote interpretation is highly accurate among multiple readers for the detection of ROP requiring treatment, but less so for detection of mild or worse ROP.

Diagnostic Techniques, Ophthalmological↗

[Diagnosis of diplopia].

Explore the source record for details and available documents.

Diagnostic Techniques, Ophthalmological↗