Search PubMed⌕ Search

PubMed · 15896945

C-reactive protein is a significant predictor of decrease in fat mass in hemodialysis patients.

Abstract

Malnutrition and inflammation are common in hemodialysis patients, and are usually closely associated. We examined annual body fat mass changes, a possible nutritional parameter, in maintenance hemodialysis patients, and investigated the factors affecting such changes. Body fat mass of 454 hemodialysis patients (61+/-11 years, 269 males and 185 females) was measured twice by dual energy X-ray absorptiometry (DEXA), with a 12-month interval between measurements. In a total of 65 patients with hemodialysis duration of less than 1 year at the first measurement, fat mass at the second measurement had increased significantly over the course of a year (P<0.0001). In contrast, in a total of 389 patients with hemodialysis duration of more than 1 year at the first measurement, fat mass at the second measurement significantly decreased (P<0.005). In the 389 patients, significant negative correlations were seen between fat mass changes and CRP (r=-0.165, P<0.005). In a multiple regression analysis, CRP was a significant factor (beta=-0.163, P<0.005) affecting fat mass changes, independent of other confounding clinical factors (R(2)=0.127, P<0.001). These results show that body fat mass of long-term hemodialysis patients decreases after an initial increase in the first to second years of hemodialysis. In hemodialysis patients, fat mass change appears to be a parameter indicative of nutritional changes. Chronic inflammation, represented by higher CRP levels, is a significant factor affecting decrease in fat mass, and is related to poorer nutritional status.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Yoko Fujino, Eiji Ishimura, Senji Okuno, Naoki Tsuboniwa, Kiyoshi Maekawa, Tsuyoshi Izumotani, Tomoyuki Yamakawa, Masaaki Inaba, Yoshiki Nishizawa. 2005. C-reactive protein is a significant predictor of decrease in fat mass in hemodialysis patients.. https://doi.org/10.1016/j.biopha.2005.04.002

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A repeated measures concordance correlation coefficient.

The concordance correlation coefficient is commonly used to assess agreement between two raters or two methods of measuring a response when the data are measured on a continuous scale. However, the situation may arise in which repeated measurements are taken for each rater or method, e.g. longitudinal studies in clinical trials or bioassay data with subsamples. This paper proposes a coefficient for measuring agreement between two raters or two methods of measuring a response in the presence of repeated measurements. We illustrate the methodology with examples comparing (1) 1-hr versus 2-hr blood draws for measuring cortisol in an asthma clinical trial and (2) two measurements of percentage body fat, from skinfold calipers and dual energy X-ray absorptiometry.

Absorptiometry, Photon↗

Crystallization and preliminary X-ray analysis of a domain in the Runx2 transcription factor that interacts with the 1alpha,25 dihydroxy vitamin D3 receptor.

The Runx2 transcription factor is a key regulator of osteoblast differentiation. In response to 1alpha,25 dihydroxy vitamin D3, Runx2 may interact with the 1alpha,25 dihydroxy vitamin D3 receptor (VDR) in the promoter of target genes, producing a synergic activation of their transcription. Previous studies have suggested that the motifs responsible for the VDR-Runx2 interaction are contained within the 230-361 domain of Runx2. In this work, we confirmed by GST-pull down that Runx2(I(209-361)) is sufficient to interact with the VDR. To obtain structural information, GST-Runx2(I(209-361)) protein was overexpressed in Escherichia coli, purified and crystallized using the hanging-drop vapor-diffusion method and polyethyleneglycol as a precipitant. The crystals were found to diffract to a maximum resolution of 2.7 A and a complete data set to a 3.3 A resolution was collected and analyzed. The crystals belong to the tetragonal system, with a space group P4 and unit-cell parameters of a = b = 90.8, and c = 57.2 A. The presence of a monomer of the recombinant GST-Runx2(I(209-361)) in the asymmetric unit gives a V(M) of 2.7 A(3) Da(-1) and a solvent content of 54.8%.

Absorptiometry, Photon↗

Quantifying the treatment effect explained by markers in the presence of measurement error.

Surrogate markers or intermediate markers are important in identifying subjects with high risk of a serious disease or for monitoring disease progression of a subject on treatment. Quantifying the proportion of treatment effect (PTE) explained by markers has been studied extensively. Due to reasons such as biological variation, limited machine precision, etc. markers are generally measured with error. The estimated PTE ignoring the measurement error could be biased, which may lead to incorrect conclusions. In this article, we adjust for the measurement error using regression calibration to construct a less biased estimator of excess relative odds, a quantity to measure the treatment effect explained by markers. The method is applied to data from a clinical study in osteoporosis.

Absorptiometry, Photon↗