Search PubMed⌕ Search

PubMed · 15879015

Levels of recent thymic emigrant cells decrease in children undergoing partial thymectomy during cardiac surgery.

Abstract

The human thymus is required for establishment of a T-cell pool in fetal life, but postnatal thymectomy is not known to cause immunodeficiency. T-cell emigration from thymus (thymic recent emigrants [TRECs]) is a continuous thymic-dependent process. We studied TREC levels pre- and post-partial thymectomy in children undergoing cardiac surgery. TRECs were quantitated by real-time PCR in peripheral blood lymphocytes of 24 children (0 to 12 years). TREC values were 47916 +/- 9271 pre-partial thymectomy and 33157 +/- 8479 post-partial thymectomy in 11 paired patients (P = 0.014). Interval between pre- and post-partial thymectomy was 8.8 days +/- 5.8 days. Another group of 8 children had 30384 +/- 9748 TRECs 16 days to 6 years post-partial thymectomy. There was a significant drop in TREC values post-partial thymectomy in the immediate postoperative period compared to prethymectomy TREC levels. While decreased thymic output may persist, the long-term implications were not evaluated in this patient population.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Ashish B Madhok, A Chandrasekran, Vincent Parnell, Mysore Gandhi, Devyani Chowdhury, Savita Pahwa. 2005. Levels of recent thymic emigrant cells decrease in children undergoing partial thymectomy during cardiac surgery.. https://doi.org/10.1128/cdli.12.5.563-565.2005. https://searchpubmed.org/record/pubmed%3A15879015/levels-of-recent-thymic-emigrant-cells-decrease-in-children-undergoing-partial-thymectomy-during-car

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Search PubMed by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related citations

3D heart model for computer simulations in cardiac surgery.

For a satisfactory computer simulation, a model, which imitates a natural situation, is needed. The Human heart is an irregular 3D object and thus difficult to reproduce. Basic data was taken from Visible Human Dataset (VHD), National Library of Medicine. The heart area was cut out of the original cross-sections and different tissues segmented. All the slices also had to be aligned to assure precise overlapping of the structures. A 3D computer heart model with the resolution of 1mm was designed. The heart model was dedicated to simulations of heat transfer during heart surgery however, it is applicable also to other medical simulations.

Cardiac Surgical Procedures↗